Network Working Group                                       J. Burchfiel
Request for Comments: 594                                      BBN-TENEX
NIC: 20616                                                 December 1973


                     Speedup of Host-IMP Interface



I. Introduction

   In order to make the full performance capabilities of the subnet
   available for interprocess communication, the host's IMP interface
   and the IMP's host interface should operate at the highest speed
   obtainable.

   First, this high throughput will minimize the latency observed when
   RFNM's, control messages, and NVT (network virtual terminal)
   characters are queued behind full sized messages.  A full-sized
   message currently ties up a 100 kb interface for almost 100 Msec.
   delaying short messages behind it by 100 Msec.  Speeding up the host
   interface to 300 kilobaud will shrink this latency to 30 Msec.

   Secondly, this high-speed operation minimizes the time that the IMP
   buffer and the host core buffer are locked down during message
   transfer. (One being emptied, one being filled).  Being able to
   dispose of buffers far faster means that many fewer of them will
   suffice to carry the communications traffic; each buffer can be
   reused far more often.

   Third, high-speed operation makes it possible to improve error
   control:  currently, a destination IMP returns an RFNM after
   transmitting the first packet of a multipacket message to the
   destination host.  If an error occurs during the transmission of the
   (up to seven) other packets into the destination host, the source
   host will not be informed of the error: it has already been given a
   positive message acknowledgement in the RFNM.  The alternative,
   holding off the RFNM until all packets have been transmitted into the
   destination host, would add another 80 Msec. to the round trip
   message - RFNM time with the current 100 kilobaud interface.  A
   higher speed interface will reduce this delayed - RFNM cost to a more
   acceptable value, making it practical to eliminate this source of
   undetected message transmission errors.








Burchfiel                                                    PAGE 1 top


RFC 594 Speedup of Host-IMP Interface December 1973 Fourth, a high speed interface will permit greater host communications bandwidth. (Currently limited to 100 kilobaud). This increase in bandwidth will be essential for communications between hosts at a "network-structured" site, where different hosts on the same IMP are specialized to perform different parts of a computation. Clearly, any new or retrofitted host interfaces should be very high speed, and existing host interfaces should be adjusted to operate at their maximum speed, which is in excess of 300 kilobaud. II. Experimental Results In support of the above predictions, the BBN TENEX staff performed an experiment in cooperation with the BBN IMP group to determine how fast the System A (BBN-TENEX) and System B (BBNB) distant interfaces would operate. Results are as follows: The Host-to-IMP connection is synchronized by a two-way handshake which has an available burst bandwidth of 1 bit/(2225 nsec + 3 nsec/ft.*<cable length>ft) For our cable length, this results in a bandwidth of 310 kilobaud. The IMP-to-Host connection is synchronized by a four-way handshake which has an available burst bandwidth of 1 bit/(1350 nsec + 6 nsec/ft.*<cable length>ft.) which results in a bandwidth of 290 kilobaud for our installation. Both System A and System B are now operating at this higher interface speed. Since the propogation delay time through a distant host driver- receiver pair amounts to 250 nsec, it is expected that local host interfaces (<30ft) can be operated at speeds substantially faster than our 300 kilobaud. In addition to the above measurements of hardware speed, new results were obtained in measurements of file transfer performance, i.e. the CPU time and real time used per megabit of information transmitted over the network. Burchfiel PAGE 2 top

RFC 594 Speedup of Host-IMP Interface December 1973 This experiment involved the movement of one-megabit data files to and from an FTP User process in System B communicating with the FTP Server Process in System A. The results are summarized in the followiing table: Operation Byte Size Type Bandwidth User CPU seconds/ megabit Get 8 ASCII 47Kbaud 7.9 Send 8 ASCII 50Kbaud 7.9 Get 32 LocalByte 43Kbaud 1.80 Send 32 LocalByte 38Kbaud 1.70 Get 36 Image 79Kbaud 1.85 Send 36 Image 85Kbaud .95 The 36-bit bandwidth of around 80Kbaud is a great improvement from the (typically 25Kbaud measured before the speedup of the interface hardware. The CPU time use has also decreased somewhat from that reported in RFC #557 by Barry Wessler: this demonstrates continued improvement of system efficiency between the TENEX version 1.31 and TENEX version 1.32. In conclusion, the BBN-TENEX staff recommends that all host-IMP interfaces in the network be speeded up to the fastest operation obtainable. [This RFC was put into machine readable form for entry] [into the online RFC archives by Alan Whinery, 1/02] Burchfiel PAGE 3 top