Network Working Group                                   O. Nicklass, Ed.
Request for Comments: 4805                 RAD Data Communications, Ltd.
Obsoletes: 3895                                               March 2007
Category: Standards Track 


                     Definitions of Managed Objects
            for the DS1, J1, E1, DS2, and E2 Interface Types

 Status of This Memo

   This document specifies an Internet standards track protocol for the
   Internet community, and requests discussion and suggestions for
   improvements.  Please refer to the current edition of the "Internet
   Official Protocol Standards" (STD 1) for the standardization state
   and status of this protocol.  Distribution of this memo is unlimited.

 Copyright Notice

   Copyright © The IETF Trust (2007).

 Abstract

   This memo defines a portion of the Management Information Base (MIB)
   for use with network management protocols in the Internet community.
   In particular, it describes objects used for managing DS1, J1, E1,
   DS2, and E2 interfaces.  This document is a companion to the
   documents that define managed objects for the DS0, DS3/E3, and
   Synchronous Optical Network/Synchronous Digital Hierarchy (SONET/SDH)
   Interface Types.

   This document obsoletes RFC 3895.



















Nicklass, Ed.               Standards Track                  PAGE 1 


RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 Table of Contents 1. The Internet-Standard Management Framework ......................2 2. Conventions Used in This Document ...............................3 3. Overview ........................................................3 3.1. Use of ifTable for DS1 Layer ...............................4 3.2. Usage Guidelines ...........................................5 3.2.1. Usage of ifStackTable for Routers and DSUs ..........5 3.2.2. Usage of ifStackTable for DS1/J1/E1 on DS2/E2 .......7 3.2.3. Usage of Channelization for DS3, DS1, DS0 ...........8 3.2.4. Usage of Channelization for DS3, DS2, DS1 ...........9 3.2.5. Usage of Loopbacks .................................10 3.3. Objectives of This MIB Module .............................10 3.4. DS1 Terminology ...........................................11 3.4.1. Error Events .......................................11 3.4.2. Performance Defects ................................12 3.4.3. Performance Parameters .............................13 3.4.4. Failure States .....................................17 3.4.5. Other Terms ........................................20 4. Object Definitions .............................................20 5. Security Considerations ........................................83 6. Acknowledgments ................................................84 7. References .....................................................84 7.1. Normative References ......................................84 7.2. Informative References ....................................86 Appendix A - Use of dsx1IfIndex and dsx1LineIndex .................88 Appendix B - The Delay Approach to Unavailable Seconds ............90 Appendix C - Changes from Previous Versions .......................92 C.1. Changes from RFC 3895 .....................................92 C.2. Changes from RFC 2495 .....................................92 C.3. Changes from RFC 1406 .....................................92 C.4. Companion Documents .......................................93 1. The Internet-Standard Management Framework For a detailed overview of the documents that describe the current Internet-Standard Management Framework, please refer to section 7 of RFC 3410 [RFC 3410]. Managed objects are accessed via a virtual information store, termed the Management Information Base or MIB. MIB objects are generally accessed through the Simple Network Management Protocol (SNMP). Objects in the MIB are defined using the mechanisms defined in the Structure of Management Information (SMI). This memo specifies a MIB module that is compliant to the SMIv2, which is described in STD 58, RFC 2578 [RFC 2578], STD 58, RFC 2579 [RFC 2579] and STD 58, RFC 2580 [RFC 2580]. Nicklass, Ed. Standards Track PAGE 2

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 2. Conventions Used in This Document The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT", "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this document are to be interpreted as described in RFC 2119 [RFC 2119]. 3. Overview These objects are used when the particular media being used to realize an interface is a DS1/J1/E1/DS2/E2 interface. At present, this applies to the following value of the ifType variable in the Internet-standard MIB: ds1 (18) The definitions contained herein are based on the AT&T T-1 Superframe (a.k.a. D4) [ANSI-T1.107] and Extended Superframe (ESF) formats [AT&T-UM-305], [AT&T-TR-54016], the latter of which conforms to ANSI specifications [ANSI-T1.403], and the CCITT Recommendations [CCITT-G.703], [ITU-T-G.704], referred to as E1 for the rest of this memo. J1 refers to the definition presented in [JT-G704], [JT-G706], and [JT-I431]. The various DS1, J1, and E1 line disciplines are similar enough that separate MIBs are unwarranted, although there are some differences. For example, Loss of Frame is defined more rigorously in the ESF specification than in the D4 specification, or Yellow Alarm generation and detection are a bit different between T1 and J1 but in both examples, there is definition in both related lines. Therefore, interface types e1(19) and g703at2mb(67) have been obsoleted and there is also no need for special type for J1. Where it is necessary to distinguish between the flavors of E1 with and without Cyclic Redundancy Check (CRC), E1-CRC denotes the "with CRC" form (G.704 Table 5B) and E1-noCRC denotes the "without CRC" form (G.704 Table 5A). Nicklass, Ed. Standards Track PAGE 3

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 3.1. Use of ifTable for DS1 Layer Only the ifGeneralInformationGroup needs to be supported. ifTable Object Use for DS1 Layer =================================================================== ifIndex Interface index. ifDescr See interfaces MIB [RFC 2863]. ifType ds1(18) ifSpeed Speed of line rate DS1 - 1544000 J1 - 1544000 E1 - 2048000 DS2 - 6312000 E2 - 8448000 ifPhysAddress The value of the Circuit Identifier. If no Circuit Identifier has been assigned, this object should have an octet string with zero length. ifAdminStatus See interfaces MIB [RFC 2863]. ifOperStatus See interfaces MIB [RFC 2863]. ifLastChange See interfaces MIB [RFC 2863]. ifName See interfaces MIB [RFC 2863]. ifLinkUpDownTrapEnable Set to enabled(1). ifHighSpeed Speed of line in mega-bits per second (2, 6, or 8). ifConnectorPresent Set to true(1) normally, except for cases such as DS1/E1 over AAL1/ATM where false(2) is appropriate. Nicklass, Ed. Standards Track PAGE 4

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 3.2. Usage Guidelines 3.2.1. Usage of ifStackTable for Routers and DSUs The object dsx1IfIndex has been deprecated. This object previously allowed a very special proxy situation to exist for routers and Channel Service Units (CSUs). This section now describes how to use the ifStackTable to represent this relationship. The paragraphs discussing dsx1IfIndex and dsx1LineIndex have been preserved in Appendix A for informational purposes. The ifStackTable is used in the proxy case to represent the association between pairs of interfaces, i.e., this T1 is attached to that T1. This use is consistent with the use of the ifStackTable to show the association between various sub-layers of an interface. In both cases, entire PDUs are exchanged between the interface pairs -- in the case of a T1, entire T1 frames are exchanged; in the case of PPP and High-Level Data Link Control (HDLC), entire HDLC frames are exchanged. This usage is not meant to suggest the use of the ifStackTable to represent Time Division Multiplexing (TDM) connections in general. External and Internal interface scenario: the SNMP agent resides on a host external from the device supporting DS1 interfaces (e.g., a router). The agent represents both the host and the DS1 device. Nicklass, Ed. Standards Track PAGE 5

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 Example: A shelf full of CSUs connected to a router. An SNMP agent residing on the router proxies for itself and the CSU. The router has also an Ethernet interface: +-----+ | | | | | | +---------------------+ |E | | 1.544 MBPS | Line#A | DS1 Link |t | R |---------------+ - - - - - - - - - +------> |h | | | | |e | O | 1.544 MBPS | Line#B | DS1 Link |r | |---------------+ - - - - - - - - - - +------> |n | U | | CSU Shelf | |e | | 1.544 MBPS | Line#C | DS1 Link |t | T |---------------+ - - - -- -- - - - - +------> | | | | | |-----| E | 1.544 MBPS | Line#D | DS1 Link | | |---------------+ - - - - -- - - - - +------> | | R | |_____________________| | | | | +-----+ The assignment of the index values could, for example, be as follows: ifIndex Description 1 Ethernet 2 Line#A Router 3 Line#B Router 4 Line#C Router 5 Line#D Router 6 Line#A CSU Router 7 Line#B CSU Router 8 Line#C CSU Router 9 Line#D CSU Router 10 Line#A CSU Network 11 Line#B CSU Network 12 Line#C CSU Network 13 Line#D CSU Network The ifStackTable is then used to show the relationships between the various DS1 interfaces. Nicklass, Ed. Standards Track PAGE 6

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 ifStackTable Entries HigherLayer LowerLayer 2 6 3 7 4 8 5 9 6 10 7 11 8 12 9 13 If the CSU shelf is managed by itself by a local SNMP agent, the situation would be identical, except the Ethernet and the four router interfaces are deleted. Interfaces would also be numbered from 1 to 8. ifIndex Description 1 Line#A CSU Router 2 Line#B CSU Router 3 Line#C CSU Router 4 Line#D CSU Router 5 Line#A CSU Network 6 Line#B CSU Network 7 Line#C CSU Network 8 Line#D CSU Network ifStackTable Entries HigherLayer LowerLayer 1 5 2 6 3 7 4 8 3.2.2. Usage of ifStackTable for DS1/J1/E1 on DS2/E2 An example is given of how DS1/J1/E1 interfaces are stacked on DS2/E2 interfaces. It is not necessary nor is it always desirable to represent DS2 interfaces. If this is required, the following stacking should be used. All ifTypes are ds1. The DS2 is determined by examining ifSpeed or dsx1LineType. Nicklass, Ed. Standards Track PAGE 7

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 ifIndex Description 1 DS1 #1 2 DS1 #2 3 DS1 #3 4 DS1 #4 5 DS2 ifStackTable Entries HigherLayer LowerLayer 1 5 2 5 3 5 4 5 3.2.3. Usage of Channelization for DS3, DS1, DS0 An example is given here to explain the channelization objects in the DS3, DS1, and DS0 MIBs to help the implementer use the objects correctly. Treatment of E3 and E1 would be similar, with the number of DS0s being different depending on the framing of the E1. Assume that a DS3 (with ifIndex 1) is channelized into DS1s (without DS2s). The object dsx3Channelization is set to enabledDs1. There will be 28 DS1s in the ifTable. Assume the entries in the ifTable for the DS1s are created in channel order and the ifIndex values are 2 through 29. In the DS1 MIB, there will be an entry in the dsx1ChanMappingTable for each DS1. The entries will be as follows: dsx1ChanMappingTable Entries ifIndex dsx1Ds1ChannelNumber dsx1ChanMappedIfIndex 1 1 2 1 2 3 ...... 1 28 29 In addition, the DS1s are channelized into DS0s. The object dsx1Channelization is set to enabledDS0 for each DS1. When this object is set to this value, 24 DS0s are created by the agent. There will be 24 DS0s in the ifTable for each DS1. If the dsx1Channelization is set to disabled, the 24 DS0s are destroyed. Assume the entries in the ifTable are created in channel order and the ifIndex values for the DS0s in the first DS1 are 30 through 53. In the DS0 MIB, there will be an entry in the dsx0ChanMappingTable for each DS0. The entries will be as follows: Nicklass, Ed. Standards Track PAGE 8

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 dsx0ChanMappingTable Entries ifIndex dsx0Ds0ChannelNumber dsx0ChanMappedIfIndex 2 1 30 2 2 31 ...... 2 24 53 3.2.4. Usage of Channelization for DS3, DS2, DS1 An example is given here to explain the channelization objects in the DS3 and DS1 MIBs to help the implementer use the objects correctly. Assume that a DS3 (with ifIndex 1) is channelized into DS2s. The object dsx3Channelization [RFC 3896] is set to enabledDs2. There will be 7 DS2s (ifType of DS1) in the ifTable. Assume the entries in the ifTable for the DS2s are created in channel order and the ifIndex values are 2 through 8. In the DS1 MIB, there will be an entry in the dsx1ChanMappingTable for each DS2. The entries will be as follows: dsx1ChanMappingTable Entries ifIndex dsx1Ds1ChannelNumber dsx1ChanMappedIfIndex 1 1 2 1 2 3 ...... 1 7 8 In addition, the DS2s are channelized into DS1s. The object dsx1Channelization is set to enabledDS1 for each DS2. There will be 4 DS1s in the ifTable for each DS2. Assume the entries in the ifTable are created in channel order and the ifIndex values for the DS1s in the first DS2 are 9 through 12, then 13 through 16 for the second DS2, and so on. In the DS1 MIB, there will be an entry in the dsx1ChanMappingTable for each DS1. The entries will be as follows: dsx1ChanMappingTable Entries ifIndex dsx1Ds1ChannelNumber dsx1ChanMappedIfIndex 2 1 9 2 2 10 2 3 11 2 4 12 3 1 13 3 2 14 ... 8 4 36 Nicklass, Ed. Standards Track PAGE 9

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 3.2.5. Usage of Loopbacks This section discusses the behavior of objects related to loopbacks. The object dsx1LoopbackConfig represents the desired state of loopbacks on this interface. Using this object, a manager can request LineLoopback PayloadLoopback (if ESF framing) InwardLoopback DualLoopback (Line + Inward) NoLoopback The remote end can also request loopbacks either through the Facility Data Link (FDL) channel if ESF or inband if D4. The loopbacks that can be requested this way are LineLoopback PayloadLoopback (if ESF framing) NoLoopback To model the current state of loopbacks on a DS1 interface, the object dsx1LoopbackStatus defines which loopback is currently applied to an interface. This object, which is a bitmap, will have bits turned on that reflect the currently active loopbacks on the interface as well as the source of those loopbacks. The following restrictions/rules apply to loopbacks: The far end cannot undo loopbacks set by a manager. A manager can undo loopbacks set by the far end. Both a line loopback and an inward loopback can be set at the same time. Only these two loopbacks can co-exist and either one may be set by the manager or the far end. A LineLoopback request from the far end is incremental to an existing Inward loopback established by a manager. When a NoLoopback is received from the far end in this case, the InwardLoopback remains in place. 3.3. Objectives of This MIB Module There are numerous things that could be included in a MIB for DS1 signals: the management of multiplexers, CSUs, Data Service Units (DSUs), and the like. The intent of this document is to facilitate the common management of all devices with DS1, J1, E1, DS2, or E2 interfaces. As such, a design decision was made up front to very Nicklass, Ed. Standards Track PAGE 10

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 closely align the MIB with the set of objects that can generally be read from these types of devices that are currently deployed. J2 interfaces are not supported by this MIB. 3.4. DS1 Terminology The terminology used in this document to describe error conditions on a DS1 interface as monitored by a DS1 device are based on the latest ANSI T1.231 standard [ANSI-T1.231]. If the definition in this document does not match the definition in the ANSI T1.231 document, the implementer should follow the definition described in this document. 3.4.1. Error Events Bipolar Violation (BPV) Error Event A BPV error event for an AMI-coded (AMI stands for Alternate Mark Inversion) signal is the occurrence of a pulse of the same polarity as the previous pulse (see T1.231, Section 4.2.1.1.1). A BPV error event for a B8ZS- or HDB3-coded signal is the occurrence of a pulse of the same polarity as the previous pulse without being a part of the zero substitution code. Excessive Zeroes (EXZ) Error Event An Excessive Zeroes error event for an AMI-coded signal is the occurrence of more than fifteen contiguous zeroes (see T1.231 Section 4.2.1.1.2). For a B8ZS-coded signal, the defect occurs when more than seven contiguous zeroes are detected. Line Coding Violation (LCV) Error Event A Line Coding Violation (LCV) is the occurrence of either a Bipolar Violation (BPV) or Excessive Zeroes (EXZ) error event. (Also known as CV-L; see T1.231, Section 4.6.1.1.) Path Coding Violation (PCV) Error Event A Path Coding Violation error event is a frame synchronization bit error in the D4 and E1-noCRC formats, or a CRC or frame synch. bit error in the ESF and E1-CRC formats. (Also known as CV-P; see T1.231, Section 4.6.2.1.) Controlled Slip (CS) Error Event A Controlled Slip is the replication or deletion of the payload bits of a DS1 frame (see T1.231, Section 4.2.1.2.3). A Controlled Slip may be performed when there is a difference between the timing of a synchronous receiving terminal and the received signal. A Controlled Slip does not cause an Out of Frame defect. Nicklass, Ed. Standards Track PAGE 11

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 3.4.2. Performance Defects Out of Frame (OOF) Defect An OOF defect is the occurrence of a particular density of Framing Error events (see T1.231, Section 4.2.2.2.1). For DS1 links, an Out of Frame defect is declared when the receiver detects two or more framing errors within a 3-msec period for ESF signals and 0.75 msec for D4 signals, or two or more errors out of five or fewer consecutive framing bits. For E1 links, an Out of Frame defect is declared when three consecutive frame alignment signals have been received with an error (see G.706, Section 4.1 [CCITT-G.706]). For DS2 links, an Out of Frame defect is declared when seven or more consecutive errored framing patterns (four multiframe) are received. The OOF is cleared when three or more consecutive correct framing patterns are received. Once an Out Of Frame Defect is declared, the framer starts searching for a correct framing pattern. The Out of Frame defect ends when the signal is in-frame. In-frame occurs when there are fewer than two frame bit errors within a 3-msec period for ESF signals and 0.75 msec for D4 signals. For E1 links, in-frame occurs when a) in frame N the frame alignment signal is correct and b) in frame N+1 the frame alignment signal is absent (i.e., bit 2 in TS0 is a one) and c) in frame N+2 the frame alignment signal is present and correct (see G.704, Section 4.1). Alarm Indication Signal (AIS) Defect For D4 and ESF links, the 'all ones' condition is detected at a DS1 line interface upon observing an unframed signal with a one's density of at least 99.9% present for a time equal to or greater than T, where 3 ms <= T <= 75 ms. The AIS is terminated upon observing a signal not meeting the one's density or the unframed signal criteria for a period equal to or greater than T (see G.775, Section 5.4). For E1 links, the 'all-ones' condition is detected at the line interface as a string of 512 bits containing fewer than three zero bits (see O.162 [ITU-T-O.162], Section 3.3.2). Nicklass, Ed. Standards Track PAGE 12

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 For DS2 links, the DS2 AIS shall be sent from the NT1 to the user to indicate a loss of the 6,312-kbps frame capability on the network side. The DS2 AIS is defined as a bit array of 6,312 kbps in which all binary bits are set to '1'. The DS2 AIS detection and removal shall be implemented according to ITU-T Draft Recommendation G.775 [ITU-T-G.775] Section 5.5: - a DS2 AIS defect is detected when the incoming signal has two or less zeroes in a sequence of 3156 bits (0.5 ms). - a DS2 AIS defect is cleared when the incoming signal has three or more zeroes in a sequence of 3156 bits (0.5 ms). 3.4.3. Performance Parameters All performance parameters are accumulated in 15-minute intervals, and up to 96 intervals (24 hours' worth) are kept by an agent. Fewer than 96 intervals of data will be available if the agent has been restarted within the last 24 hours. In addition, there is a rolling 24-hour total of each performance parameter. Performance parameters continue to be collected when the interface is down. There is no requirement for an agent to ensure a fixed relationship between the start of a 15-minute interval and any wall clock; however, some agents may align the 15-minute intervals with quarter hours. Performance parameters are of types PerfCurrentCount, PerfIntervalCount, and PerfTotalCount. These textual conventions are all Gauge32, and they are used because it is possible for these objects to decrease. Objects may decrease when Unavailable Seconds occur across a 15-minute interval boundary. See Unavailable Second discussion later in this section. Line Errored Second (LES) A Line Errored Second is a second in which one or more Line Coding Violation error events were detected. (Also known as ES-L; see T1.231, Section 4.6.1.2.) Controlled Slip Second (CSS) A Controlled Slip Second is a one-second interval containing one or more controlled slips (see T1.231, Section 4.6.2.9). This is not incremented during an Unavailable Second. Nicklass, Ed. Standards Track PAGE 13

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 Errored Second (ES) For ESF and E1-CRC links, an Errored Second is a second with one or more Path Coding Violations OR one or more Out of Frame defects OR one or more Controlled Slip events OR a detected AIS defect. (See T1.231, Section 4.6.2.2 and G.826 [ITU-T-G.826], Section B.1). For D4 and E1-noCRC links, the presence of Bipolar Violations also triggers an Errored Second. This is not incremented during an Unavailable Second. Bursty Errored Second (BES) A Bursty Errored Second (also known as Errored Second type B in T1.231, Section 4.6.2.4) is a second with fewer than 320 and more than 1 Path Coding Violation error events, no Severely Errored Frame defects, and no detected incoming AIS defects. Controlled Slips are not included in this parameter. This is not incremented during an Unavailable Second. It applies to ESF signals only. Severely Errored Second (SES) A Severely Errored Second for ESF signals is a second with 320 or more Path Coding Violation error events OR one or more Out of Frame defects OR a detected AIS defect (see T1.231, Section 4.6.2.5). For E1-CRC signals, a Severely Errored Second is a second with 832 or more Path Coding Violation error events OR one or more Out of Frame defects. For E1-noCRC signals, a Severely Errored Second is 2048 LCVs or more. For D4 signals, a Severely Errored Second is a count of one-second intervals with Framing Error events, or an OOF defect, or 1544 LCVs or more. Controlled Slips are not included in this parameter. This is not incremented during an Unavailable Second. Severely Errored Framing Second (SEFS) An Severely Errored Framing Second is a second with one or more Out of Frame defects OR a detected AIS defect. (Also known as SAS-P (SEF/AIS second); see T1.231, Section 4.6.2.6.) Nicklass, Ed. Standards Track PAGE 14

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 Degraded Minutes A Degraded Minute is one in which the estimated error rate exceeds 1E-6 but does not exceed 1E-3 (see G.821 [CCITT-G.821]). Degraded Minutes are determined by collecting all of the Available Seconds, removing any Severely Errored Seconds, grouping the result in 60-second long groups, and counting a 60-second long group (a.k.a. minute) as degraded if the cumulative errors during the seconds present in the group exceed 1E-6. Available seconds are merely those seconds that are not Unavailable as described below. Unavailable Second (UAS) Unavailable Seconds (UASs) are calculated by counting the number of seconds that the interface is unavailable. The DS1 interface is said to be unavailable from the onset of 10 contiguous SESs, or the onset of the condition leading to a failure (see Failure States). If the condition leading to the failure was immediately preceded by one or more contiguous SESs, then the DS1 interface unavailability starts from the onset of these SESs. Once unavailable, and if no failure is present, the DS1 interface becomes available at the onset of 10 contiguous seconds with no SESs. Once unavailable, and if a failure is present, the DS1 interface becomes available at the onset of 10 contiguous seconds with no SESs, if the failure clearing time is less than or equal to 10 seconds. If the failure clearing time is more than 10 seconds, the DS1 interface becomes available at the onset of 10 contiguous seconds with no SESs, or the onset period leading to the successful clearing condition, whichever occurs later. With respect to the DS1 error counts, all counters are incremented while the DS1 interface is deemed available. While the interface is deemed unavailable, the only count that is incremented is UASs. Note that this definition implies that the agent cannot determine until after a 10-second interval has passed whether a given one- second interval belongs to available or unavailable time. If the agent chooses to update the various performance statistics in real time, then it must be prepared to retroactively reduce the ES, BES, SES, and SEFS counts by 10 and increase the UAS count by 10 when it determines that available time has been entered. It must also be prepared to adjust the PCV count and the DM count as necessary since these parameters are not accumulated during unavailable time. It must be similarly prepared to retroactively decrease the UAS count by 10 and increase the ES, BES, and DM counts as necessary upon entering available time. A special case exists when the 10-second period leading to available or unavailable time crosses a 900-second statistics window boundary, as the foregoing description implies that the ES, BES, SES, SEFS, Nicklass, Ed. Standards Track PAGE 15

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 DM, and UAS counts the PREVIOUS interval must be adjusted. In this case, successive GETs of the affected dsx1IntervalSESs and dsx1IntervalUASs objects will return differing values if the first GET occurs during the first few seconds of the window. The agent may instead choose to delay updates to the various statistics by 10 seconds in order to avoid retroactive adjustments to the counters. A way to do this is sketched in Appendix B. In any case, a linkDown trap shall be sent only after the agent has determined for certain that the unavailable state has been entered, but the time on the trap will be that of the first UAS (i.e., 10 seconds earlier). A linkUp trap shall be handled similarly. According to ANSI T1.231, unavailable time begins at the onset of 10 contiguous severely errored seconds -- that is, unavailable time starts with the first of the 10 contiguous SESs. Also, while an interface is deemed unavailable all counters for that interface are frozen except for the UAS count. It follows that an implementation that strictly complies with this standard must not increment any counters other than the UAS count -- even temporarily -- as a result of anything that happens during those 10 seconds. Since changes in the signal state lag the data to which they apply by 10 seconds, an ANSI-compliant implementation must pass the one-second statistics through a 10-second delay line prior to updating any counters. That can be done by performing the following steps at the end of each one-second interval. i) Read near/far end CV counter and alarm status flags from the hardware. ii) Accumulate the CV counts for the preceding second and compare them to the ES and SES threshold for the layer in question. Update the signal state and shift the one-second CV counts and ES/SES flags into the 10-element delay line. Note that far-end one-second statistics are to be flagged as "absent" during any second in which there is an incoming defect at the layer in question or at any lower layer. iii) Update the current interval statistics using the signal state from the previous update cycle and the one-second CV counts and ES/SES flags shifted out of the 10-element delay line. This approach is further described in Appendix B. Nicklass, Ed. Standards Track PAGE 16

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 3.4.4. Failure States The following failure states are received, or detected failures, that are reported in the dsx1LineStatus object. When a DS1 interface would, if ever, produce the conditions leading to the failure state is described in the appropriate specification. Far End Alarm Failure The Far End Alarm failure is also known as "Yellow Alarm" in the DS1 and J1 cases, "Distant Alarm" in the E1 case, and "Remote Alarm" in the DS2 case. For D4 links, the Far End Alarm failure is declared when bit 6 of all channels has been zero for at least 335 ms and is cleared when bit 6 of at least one channel is non-zero for a period T, where T is usually less than one second and always less than five seconds. The Far End Alarm failure is not declared for D4 links when a Loss of Signal is detected. In J1 the 12th F-bit is set to 1. For ESF links, the Far End Alarm failure is declared if the Yellow Alarm signal pattern occurs in at least seven out of ten contiguous 16-bit pattern intervals and is cleared if the Yellow Alarm signal pattern does not occur in ten contiguous 16-bit signal pattern intervals. For DS1 the patterns is FF00 and for J1 the pattern is FFFF. For E1 links, the Far End Alarm failure is declared when bit 3 of time-slot zero is received set to one on two consecutive occasions. The Far End Alarm failure is cleared when bit 3 of time-slot zero is received set to zero. For DS2 links, if a loss of frame alignment (LOF or LOS) and/or DS2 AIS condition is detected, the RAI signal shall be generated and transmitted to the remote side. The Remote Alarm Indication (RAI) signal is defined on m-bits as a repetition of the 16-bit sequence consisting of eight binary '1s' and eight binary '0s' in m-bits(1111111100000000). When the RAI signal is not sent (in normal operation), the HDLC flag pattern (01111110) in the m-bit is sent. The RAI failure is detected when 16 or more consecutive RAI- patterns (1111111100000000) are received. The RAI failure is cleared when 4 or more consecutive incorrect-RAI-patterns are received. Nicklass, Ed. Standards Track PAGE 17

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 Alarm Indication Signal (AIS) Failure The Alarm Indication Signal failure is declared when an AIS defect is detected at the input and the AIS defect still exists after the Loss of Frame failure (which is caused by the unframed nature of the 'all-ones' signal) is declared. The AIS failure is cleared when the Loss of Frame failure is cleared. (See T1.231, Section 4.3.1.2.2). An AIS defect at a 6312-kbit/s (G.704) interface is detected when the incoming signal has two or less zeroes in a sequence of 3156 bits (0.5ms). The AIS signal defect is cleared when the incoming signal has three {3} or more zeroes in a sequence of 3156 bits (0.5ms). Loss Of Frame (LOF) Failure For DS1 links, the Loss of Frame failure is declared when an OOF or LOS defect has persisted for T seconds, where 2 <= T <= 10. The Loss of Frame failure is cleared when there have been no OOF or LOS defects during a period T where 0 <= T <= 20. Many systems will perform "hit integration" within the period T before declaring or clearing the failure; e.g., see TR 62411 [AT&T-TR-62411]. For E1 links, the Loss of Frame failure is declared when an OOF defect is detected. Loss Of Signal (LOS) Failure For DS1, the Loss of Signal failure is declared upon observing 175 +/- 75 contiguous pulse positions with no pulses of either positive or negative polarity. The LOS failure is cleared upon observing an average pulse density of at least 12.5% over a period of 175 +/- 75 contiguous pulse positions starting with the receipt of a pulse. For E1 links, the Loss of Signal failure is declared when greater than 10 consecutive zeroes are detected (see O.162, Section 3.4.4). A LOS defect at 6312kbit/s interfaces is detected when the incoming signal has "no transitions", i.e., when the signal level is less than or equal to a signal level of 35dB below nominal, for N consecutive pulse intervals, where 10 <= N <= 255. The LOS defect is cleared when the incoming signal has "transitions", i.e., when the signal level is greater than or equal to a signal level of 9dB below nominal, for N consecutive pulse intervals, where 10 <= N <= 255. Nicklass, Ed. Standards Track PAGE 18

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 A signal with "transitions" corresponds to a G.703-compliant signal. Loopback Pseudo-Failure The Loopback Pseudo-Failure is declared when the near-end equipment has placed a loopback (of any kind) on the DS1. This allows a management entity to determine from one object whether the DS1 can be considered to be in service or not (from the point of view of the near-end equipment). TS16 Alarm Indication Signal Failure For E1 links, the TS16 Alarm Indication Signal failure is declared when time-slot 16 is received as all ones for all frames of two consecutive multiframes (see G.732, Section 4.2.6). This condition is never declared for DS1. Loss of MultiFrame Failure The Loss of MultiFrame failure is declared when two consecutive multiframe alignment signals (bits 4 through 7 of TS16 of frame 0) have been received with an error. The Loss of Multiframe failure is cleared when the first correct multiframe alignment signal is received. The Loss of Multiframe failure can only be declared for E1 links operating with G.732 [CCITT-G.732] framing (sometimes called "Channel Associated Signalling" mode). Far End Loss of Multiframe Failure The Far End Loss of Multiframe failure is declared when bit 2 of TS16 of frame 0 is received set to one on two consecutive occasions. The Far End Loss of Multiframe failure is cleared when bit 2 of TS16 of frame 0 is received set to zero. The Far End Loss of Multiframe failure can only be declared for E1 links operating in "Channel Associated Signalling" mode (see G.732). DS2 Payload AIS Failure The DS2 Payload AIS failure is declared when the incoming signal of the 6,312-kbps frame payload (time-slots 1 through 96) has two or less zeroes in a sequence of 3072 bits (0.5ms). The DS2 Payload AIS is cleared when the incoming signal of the 6,312-kbps frame payload has three or more zeroes in a sequence of 3072 bits (0.5 ms). DS2 Performance Threshold Failure DS2 Performance Threshold failure monitors equipment performance and is based on the CRC (Cyclic Redundancy Check) procedure defined in G.704. The DS2 Performance Threshold failure is declared when the bit error ratio exceeds 10^-4 (Performance Threshold), and the DS2 Nicklass, Ed. Standards Track PAGE 19

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 Performance Threshold failure is cleared when the bit error ratio decreases to less than 10^-6." 3.4.5. Other Terms Circuit Identifier This is a character string specified by the circuit vendor and is useful when communicating with the vendor during the troubleshooting process (see M.1400 [ITU-T-M.1400] for additional information). Proxy In this document, the word proxy is meant to indicate an application that receives SNMP messages and replies to them on behalf of the devices that implement the actual DS1/E1 interfaces. The proxy may have already collected the information about the DS1/J1/E1 interfaces into its local database and may not necessarily forward the requests to the actual DS1/J1/E1 interface. It is expected in such an application that there are periods of time where the proxy is not communicating with the DS1/J1/E1 interfaces. In these instances, the proxy will not necessarily have up-to-date configuration information and will most likely have missed the collection of some statistics data. Missed statistics data collection will result in invalid data in the interval table. 4. Object Definitions DS1-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, transmission FROM SNMPv2-SMI -- [RFC 2578] DisplayString, TimeStamp, TruthValue FROM SNMPv2-TC -- [RFC 2579] MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF -- [RFC 2580] InterfaceIndex, ifIndex FROM IF-MIB -- [RFC 2863] PerfCurrentCount, PerfIntervalCount, PerfTotalCount FROM PerfHist-TC-MIB; -- [RFC 3593] ds1 MODULE-IDENTITY LAST-UPDATED "200703050000Z" ORGANIZATION "IETF AToM MIB Working Group" Nicklass, Ed. Standards Track PAGE 20

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 CONTACT-INFO "WG charter: http://www.ietf.org/html.charters/atommib-charter.html Mailing Lists: General Discussion: atommib@research.telcordia.com To Subscribe: atommib-request@research.telcordia.com Editor: Orly Nicklass Postal: RAD Data Communications, Ltd. Ziv Tower, 24 Roul Walenberg Tel Aviv, Israel, 69719 Tel: +9723 765 9969 E-mail: orly_n@rad.com" DESCRIPTION "The MIB module to describe DS1, J1, E1, DS2, and E2 interfaces objects. Copyright (c) The IETF Trust (2007). This version of this MIB module is part of RFC 4805; see the RFC itself for full legal notices." REVISION "200703050000Z" DESCRIPTION "The following changes were made: (1) Values were added to dsx1LineType to support J1 types. (2) The object dsx1LineImpedance was added. (3) All DM-related objects were deprecated following their removal from ITU performance standards. The RFC 4805 version of this MIB module." REVISION "200409090000Z" DESCRIPTION "The RFC 3895 version of this MIB module. The key changes made to this MIB module since its publication in RFC 2495 are as follows: (1) The dsx1FracIfIndex SYNTAX matches the description range. (2) A value was added to dsx1TransmitClockSource. (3) Values were added to dsx1LineType. (4) Two objects were added, dsx1LineMode and dsx1LineBuildOut, to better express transceiver mode and LineBuildOut for T1. (5) Reference was added to Circuit Identifier object. Nicklass, Ed. Standards Track PAGE 21

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 (6) Align the DESCRIPTION clauses of few statistic objects with the near-end definition, with the far-end definition, and with RFC 3593. (7) Changes in Compliance Statements to include new objects. (8) A typographical error in dsx2E2 was fixed; the new name is dsx1E2." REVISION "199808011830Z" DESCRIPTION "The RFC 2495 version of this MIB module. The key changes made to this MIB module since its publication in RFC 1406 are as follows: (1) The Fractional table has been deprecated. (2) This document uses SMIv2. (3) Usage is given for ifTable and ifXTable. (4) Example usage of ifStackTable is included. (5) dsx1IfIndex has been deprecated. (6) Support for DS2 and E2 has been added. (7) Additional lineTypes for DS2, E2, and unframed E1 were added. (8) The definition of valid intervals has been clarified for the case where the agent proxied for other devices. In particular, the treatment of missing intervals has been clarified. (9) An inward loopback has been added. (10) Additional lineStatus bits have been added for Near End in Unavailable Signal State, Carrier Equipment Out of Service, DS2 Payload AIS, and DS2 Performance Threshold. (11) A read-write line Length object has been added. (12) Signal mode of other has been added. (13) Added a lineStatus last change, trap and enabler. (14) The e1(19) ifType has been obsoleted, so this MIB does not list it as a supported ifType. (15) Textual Conventions for statistics objects have been used. (16) A new object, dsx1LoopbackStatus, has been introduced to reflect the loopbacks established on a DS1 interface and the source to the requests. dsx1LoopbackConfig continues to be the desired loopback state while dsx1LoopbackStatus reflects the actual state. (17) A dual loopback has been added to allow the setting of an inward loopback and a line loopback at the same time. (18) An object indicating which channel to use within a parent object (i.e., DS3) has been added. Nicklass, Ed. Standards Track PAGE 22

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 (19) An object has been added to indicate whether or not this DS1/E1 is channelized. (20) Line coding type of B6ZS has been added for DS2." REVISION "199301252028Z" DESCRIPTION "Initial version, published as RFC 1406." ::= { transmission 18 } -- note that this subsumes cept(19) and g703at2mb(67) -- there is no separate CEPT or G703AT2MB MIB -- The DS1 Near End Group -- The DS1 Near End Group consists of five tables: -- DS1 Configuration -- DS1 Current -- DS1 Interval -- DS1 Total -- DS1 Channel Table -- The DS1 Configuration Table dsx1ConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx1ConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DS1 Configuration table." ::= { ds1 6 } dsx1ConfigEntry OBJECT-TYPE SYNTAX Dsx1ConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the DS1 Configuration table." INDEX { dsx1LineIndex } ::= { dsx1ConfigTable 1 } Dsx1ConfigEntry ::= SEQUENCE { dsx1LineIndex InterfaceIndex, dsx1IfIndex InterfaceIndex, dsx1TimeElapsed INTEGER, dsx1ValidIntervals INTEGER, dsx1LineType INTEGER, dsx1LineCoding INTEGER, dsx1SendCode INTEGER, Nicklass, Ed. Standards Track PAGE 23

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 dsx1CircuitIdentifier DisplayString, dsx1LoopbackConfig INTEGER, dsx1LineStatus INTEGER, dsx1SignalMode INTEGER, dsx1TransmitClockSource INTEGER, dsx1Fdl INTEGER, dsx1InvalidIntervals INTEGER, dsx1LineLength INTEGER, dsx1LineStatusLastChange TimeStamp, dsx1LineStatusChangeTrapEnable INTEGER, dsx1LoopbackStatus INTEGER, dsx1Ds1ChannelNumber INTEGER, dsx1Channelization INTEGER, dsx1LineMode INTEGER, dsx1LineBuildOut INTEGER, dsx1LineImpedance INTEGER } dsx1LineIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only -- read-only since originally an -- SMIv1 index STATUS current DESCRIPTION "This object should be made equal to ifIndex. The next paragraph describes its previous usage. Making the object equal to ifIndex allows proper use of the ifStackTable and ds0/ds0bundle MIBs. Previously, this object was the identifier of a DS1 interface on a managed device. If there is an ifEntry that is directly associated with this and only this DS1 interface, it should have the same value as ifIndex. Otherwise, number the dsx1LineIndices with a unique identifier following the rules of choosing a number that is greater than ifNumber and numbering the inside interfaces (e.g., equipment side) with even numbers and outside interfaces (e.g., network side) with odd numbers." ::= { dsx1ConfigEntry 1 } dsx1IfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This value for this object is equal to the value Nicklass, Ed. Standards Track PAGE 24

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 of ifIndex from the Interfaces table (RFC 2863)." ::= { dsx1ConfigEntry 2 } dsx1TimeElapsed OBJECT-TYPE SYNTAX INTEGER (0..899) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of seconds that have elapsed since the beginning of the near-end current error- measurement period. If, for some reason, such as an adjustment in the system's time-of-day clock, the current interval exceeds the maximum value, the agent will return the maximum value." ::= { dsx1ConfigEntry 3 } dsx1ValidIntervals OBJECT-TYPE SYNTAX INTEGER (0..96) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of previous near-end intervals for which data was collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of complete 15-minute near-end intervals since the interface has been online. In the case where the agent is a proxy, it is possible that some intervals are unavailable. In this case, this interval is the maximum interval number for which data is available." ::= { dsx1ConfigEntry 4 } dsx1LineType OBJECT-TYPE SYNTAX INTEGER { other(1), dsx1ESF(2), dsx1D4(3), dsx1E1(4), dsx1E1CRC(5), dsx1E1MF(6), dsx1E1CRCMF(7), dsx1Unframed(8), dsx1E1Unframed(9), dsx1DS2M12(10), dsx1E2(11), dsx1E1Q50(12), dsx1E1Q50CRC(13), Nicklass, Ed. Standards Track PAGE 25

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 dsx1J1ESF(14), dsx1J1Unframed(16) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable indicates the variety of DS1 Line implementing this circuit. The type of circuit affects the number of bits per second that the circuit can reasonably carry, as well as the interpretation of the usage and error statistics. The values, in sequence, describe: TITLE: SPECIFICATION: dsx1ESF Extended SuperFrame DS1 (T1.107) dsx1D4 AT&T D4 format DS1 (T1.107) dsx1E1 ITU-T G.704, (Table 5A) dsx1E1-CRC ITU-T G.704, (Table 5B) dsxE1-MF G.704 (Table 5A) with TS16 multiframing enabled dsx1E1-CRC-MF G.704 (Table 5B) with TS16 multiframing enabled dsx1Unframed DS1 with No Framing dsx1E1Unframed E1 with No Framing (G.703) dsx1DS2M12 DS2 frame format (T1.107) dsx1E2 E2 frame format (G.704) dsx1E1Q50 TS16 bits 5,7,8 set to 101, [in all other cases it is set to 111.] (G.704, table 14) dsx1E1Q50CRC E1Q50 with CRC dsx1J1ESF J1 according to (JT-G704, JT-G706, and JT-I431) dsx1J1Unframed J1 with No Framing For clarification, the capacity for each E1 type is as listed below: dsx1E1Unframed - E1, no framing = 32 x 64k = 2048k dsx1E1 or dsx1E1CRC - E1, with framing, no signalling = 31 x 64k = 1984k dsx1E1MF or dsx1E1CRCMF - E1, with framing, signalling = 30 x 64k = 1920k" REFERENCE "American National Standard for telecommunications - digital hierarchy - formats specification, ANSI T1.107- 1988. ITU-T G.703: Physical/Electrical Characteristics Nicklass, Ed. Standards Track PAGE 26

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 of Hierarchical Digital Interfaces, November 2001. ITU-T G.704: Synchronous frame structures used at 1544, 6312, 2048, 8488 and 44 736 kbit/s Hierarchical Levels, July 1995. JT-G704: Synchronous frame structures used at Primary and Secondary Hierarchical Levels,2002. JT-G706. Frame Alignment and Cyclic Redundancy Check (CRC) Procedures. JT-I431. ISDN Primary Rate User-Network Interface, Layer 1 Specifications, 2002 " ::= { dsx1ConfigEntry 5 } dsx1LineCoding OBJECT-TYPE SYNTAX INTEGER { dsx1JBZS(1), dsx1B8ZS(2), dsx1HDB3(3), dsx1ZBTSI(4), dsx1AMI(5), other(6), dsx1B6ZS(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable describes the variety of Zero Code Suppression used on this interface, which in turn affects a number of its characteristics. dsx1JBZS refers the Jammed Bit Zero Suppression, in which the AT&T specification of at least one pulse every 8-bit period is literally implemented by forcing a pulse in bit 8 of each channel. Thus, only 7 bits per channel, or 1.344 Mbps, are available for data. dsx1B8ZS refers to the use of a specified pattern of normal bits and bipolar violations that are used to replace a sequence of 8 zero bits. ANSI Clear Channels may use dsx1ZBTSI, or Zero Byte Time Slot Interchange. E1 links, with or without CRC, use dsx1HDB3 or dsx1AMI. dsx1AMI refers to a mode wherein no Zero Code Suppression is present and the line encoding does Nicklass, Ed. Standards Track PAGE 27

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 not solve the problem directly. In this application, the higher layer must provide data that meets or exceeds the pulse density requirements, such as inverting HDLC data. dsx1B6ZS refers to the user of a specified pattern of normal bits and bipolar violations that are used to replace a sequence of 6 zero bits. Used for DS2. For more information about line coding see [ANSI-T1.102]" ::= { dsx1ConfigEntry 6 } dsx1SendCode OBJECT-TYPE SYNTAX INTEGER { dsx1SendNoCode(1), dsx1SendLineCode(2), dsx1SendPayloadCode(3), dsx1SendResetCode(4), dsx1SendQRS(5), dsx1Send511Pattern(6), dsx1Send3in24Pattern(7), dsx1SendOtherTestPattern(8) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable indicates what type of code is being sent across the DS1 interface by the device. Setting this variable causes the interface to send the code requested. The values mean the following: dsx1SendNoCode sending looped or normal data dsx1SendLineCode sending a request for a line loopback dsx1SendPayloadCode sending a request for a payload loopback dsx1SendResetCode sending a loopback termination request dsx1SendQRS sending a Quasi-Random Signal (QRS) test pattern Nicklass, Ed. Standards Track PAGE 28

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 dsx1Send511Pattern sending a 511-bit fixed test pattern dsx1Send3in24Pattern sending a fixed test pattern of 3 bits set in 24 dsx1SendOtherTestPattern sending a test pattern other than those described by this object" ::= { dsx1ConfigEntry 7 } dsx1CircuitIdentifier OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This variable contains the transmission vendor's circuit identifier, for the purpose of facilitating troubleshooting." REFERENCE "ITU-T M.1400" ::= { dsx1ConfigEntry 8 } dsx1LoopbackConfig OBJECT-TYPE SYNTAX INTEGER { dsx1NoLoop(1), dsx1PayloadLoop(2), dsx1LineLoop(3), dsx1OtherLoop(4), dsx1InwardLoop(5), dsx1DualLoop(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable represents the desired loopback configuration of the DS1 interface. Agents supporting read/write access should return inconsistentValue in response to a requested loopback state that the interface does not support. The values mean: dsx1NoLoop not in the loopback state. A device that is not capable of performing a loopback on the interface shall always return this as its value. dsx1PayloadLoop Nicklass, Ed. Standards Track PAGE 29

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 the received signal at this interface is looped through the device. Typically, the received signal is looped back for retransmission after it has passed through the device's framing function. dsx1LineLoop the received signal at this interface does not go through the device (minimum penetration) but is looped back out. dsx1OtherLoop loopbacks that are not defined here. dsx1InwardLoop the transmitted signal at this interface is looped back and received by the same interface. What is transmitted onto the line is product dependent. dsx1DualLoop both dsx1LineLoop and dsx1InwardLoop will be active simultaneously." ::= { dsx1ConfigEntry 9 } dsx1LineStatus OBJECT-TYPE SYNTAX INTEGER (1..131071) MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates the line status of the interface. It contains loopback, failure, received alarm and transmitted alarms information. The dsx1LineStatus is a bitmap represented as a sum; therefore, it can represent multiple failures (alarms) and a LoopbackState simultaneously. dsx1NoAlarm must be set if and only if no other flag is set. If the dsx1loopbackState bit is set, the loopback in effect can be determined from the dsx1loopbackConfig object. The various bit positions are as follows: 1 dsx1NoAlarm No alarm present 2 dsx1RcvFarEndLOF Far end LOF (a.k.a. Nicklass, Ed. Standards Track PAGE 30

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 Yellow Alarm) 4 dsx1XmtFarEndLOF Near end sending LOF indication 8 dsx1RcvAIS Far end sending AIS 16 dsx1XmtAIS Near end sending AIS 32 dsx1LossOfFrame Near end LOF (a.k.a. Red Alarm) 64 dsx1LossOfSignal Near end Loss of Signal 128 dsx1LoopbackState Near end is looped 256 dsx1T16AIS E1 TS16 AIS 512 dsx1RcvFarEndLOMF Far end sending TS16 LOMF 1024 dsx1XmtFarEndLOMF Near end sending TS16 LOMF 2048 dsx1RcvTestCode Near end detects a test code 4096 dsx1OtherFailure Any line status not defined here 8192 dsx1UnavailSigState Near end in unavailable signal state 16384 dsx1NetEquipOOS Carrier equipment out of service 32768 dsx1RcvPayloadAIS DS2 payload AIS 65536 dsx1Ds2PerfThreshold DS2 performance threshold exceeded" ::= { dsx1ConfigEntry 10 } dsx1SignalMode OBJECT-TYPE SYNTAX INTEGER { none(1), robbedBit(2), bitOriented(3), messageOriented(4), other(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "'none' indicates that no bits are reserved for signaling on this channel. 'robbedBit' indicates that DS1 Robbed Bit Signaling is in use. 'bitOriented' indicates that E1 Channel Associated Signaling is in use. 'messageOriented' indicates that Common Channel Signaling is in use on either channel 16 of an E1 link or channel 24 of a DS1." ::= { dsx1ConfigEntry 11 } Nicklass, Ed. Standards Track PAGE 31

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 dsx1TransmitClockSource OBJECT-TYPE SYNTAX INTEGER { loopTiming(1), localTiming(2), throughTiming(3), adaptive (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The source of transmit clock. 'loopTiming' indicates that the recovered receive clock is used as the transmit clock. 'localTiming' indicates that a local clock source is used or when an external clock is attached to the box containing the interface. 'throughTiming' indicates that recovered receive clock from another interface is used as the transmit clock. 'adaptive' indicates that the clock is recovered based on the data flow and not based on the physical layer" ::= { dsx1ConfigEntry 12 } dsx1Fdl OBJECT-TYPE SYNTAX INTEGER (1..15) MAX-ACCESS read-write STATUS current DESCRIPTION "This bitmap describes the use of the facilities data link and is the sum of the capabilities. Set any bits that are appropriate: other(1), dsx1AnsiT1403(2), dsx1Att54016(4), dsx1FdlNone(8) 'other' indicates that a protocol other than one of the following is used. 'dsx1AnsiT1403' refers to the FDL exchange recommended by ANSI. Nicklass, Ed. Standards Track PAGE 32

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 'dsx1Att54016' refers to ESF FDL exchanges. 'dsx1FdlNone' indicates that the device does not use the FDL." ::= { dsx1ConfigEntry 13 } dsx1InvalidIntervals OBJECT-TYPE SYNTAX INTEGER (0..96) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of intervals in the range from 0 to dsx1ValidIntervals for which no data is available. This object will typically be zero except in cases where the data for some intervals is not available (e.g., in proxy situations)." ::= { dsx1ConfigEntry 14 } dsx1LineLength OBJECT-TYPE SYNTAX INTEGER (0..64000) UNITS "meters" MAX-ACCESS read-write STATUS current DESCRIPTION "The length of the DS1 line in meters. This object provides information for line build-out circuitry. This object is only useful if the interface has configurable line build-out circuitry." ::= { dsx1ConfigEntry 15 } dsx1LineStatusLastChange OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of MIB II's sysUpTime object at the time this DS1 entered its current line status state. If the current state was entered prior to the last re-initialization of the proxy-agent, then this object contains a zero value." ::= { dsx1ConfigEntry 16 } dsx1LineStatusChangeTrapEnable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } Nicklass, Ed. Standards Track PAGE 33

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether dsx1LineStatusChange traps should be generated for this interface." DEFVAL { disabled } ::= { dsx1ConfigEntry 17 } dsx1LoopbackStatus OBJECT-TYPE SYNTAX INTEGER (1..127) MAX-ACCESS read-only STATUS current DESCRIPTION "This variable represents the current state of the loopback on the DS1 interface. It contains information about loopbacks established by a manager and remotely from the far end. The dsx1LoopbackStatus is a bitmap represented as a sum; therefore, it can represent multiple loopbacks simultaneously. The various bit positions are as follows: 1 dsx1NoLoopback 2 dsx1NearEndPayloadLoopback 4 dsx1NearEndLineLoopback 8 dsx1NearEndOtherLoopback 16 dsx1NearEndInwardLoopback 32 dsx1FarEndPayloadLoopback 64 dsx1FarEndLineLoopback" ::= { dsx1ConfigEntry 18 } dsx1Ds1ChannelNumber OBJECT-TYPE SYNTAX INTEGER (0..28) MAX-ACCESS read-only STATUS current DESCRIPTION "This variable represents the channel number of the DS1/E1 on its parent DS2/E2 or DS3/E3. A value of 0 indicates that this DS1/E1 does not have a parent DS3/E3." ::= { dsx1ConfigEntry 19 } dsx1Channelization OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabledDs0(2), Nicklass, Ed. Standards Track PAGE 34

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 enabledDs1(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether this DS1/E1 or DS2 is channelized or unchannelized. The value of enabledDs0(2) indicates that this is a DS1 channelized into DS0s. Setting this value will cause the creation, and resetting it to disabled(1) will cause the deletion of entries in the ifTable for the DS0s that are within the DS1. The value of enabledDs1(3) indicates that this is a DS2 channelized into DS1s. Setting this value will cause the creation, and resetting it to disabled(1) will cause the deletion of entries in the ifTable for the DS1s that are within the DS2." ::= { dsx1ConfigEntry 20 } dsx1LineMode OBJECT-TYPE SYNTAX INTEGER { csu(1), dsu(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This setting puts the T1 framer into either long-haul (CSU) mode or short-haul (DSU) mode." ::= { dsx1ConfigEntry 21 } dsx1LineBuildOut OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), neg75dB(2), neg15dB(3), neg225dB(4), zerodB(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Attenuation setting for T1 framer in long haul (CSU) mode. The optional values are -7.5dB, -15dB, -22.5dB, and 0dB." Nicklass, Ed. Standards Track PAGE 35

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 ::= { dsx1ConfigEntry 22 } dsx1LineImpedance OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), unbalanced75ohms(2), balanced100ohms(3), balanced120ohms(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Nominal line impedance. For T1 and J1 lines, the value is typically balanced100ohms(3). For E1 lines, the value is typically unbalanced75ohms(2) and balanced120ohms(4). When this object does not apply, or when the appropriate value is not known, the value should be set to notApplicable(1)." ::= { dsx1ConfigEntry 23 } -- The DS1 Current Table dsx1CurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx1CurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DS1 Current table contains various statistics being collected for the current 15-minute interval." ::= { ds1 7 } dsx1CurrentEntry OBJECT-TYPE SYNTAX Dsx1CurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the DS1 Current table." INDEX { dsx1CurrentIndex } ::= { dsx1CurrentTable 1 } Dsx1CurrentEntry ::= SEQUENCE { dsx1CurrentIndex InterfaceIndex, dsx1CurrentESs PerfCurrentCount, dsx1CurrentSESs PerfCurrentCount, dsx1CurrentSEFSs PerfCurrentCount, dsx1CurrentUASs PerfCurrentCount, dsx1CurrentCSSs PerfCurrentCount, Nicklass, Ed. Standards Track PAGE 36

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 dsx1CurrentPCVs PerfCurrentCount, dsx1CurrentLESs PerfCurrentCount, dsx1CurrentBESs PerfCurrentCount, dsx1CurrentDMs PerfCurrentCount, dsx1CurrentLCVs PerfCurrentCount } dsx1CurrentIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only -- read-only since originally an -- SMIv1 index STATUS current DESCRIPTION "The index value that uniquely identifies the DS1 interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value as a dsx1LineIndex object instance." ::= { dsx1CurrentEntry 1 } dsx1CurrentESs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Errored Seconds." ::= { dsx1CurrentEntry 2 } dsx1CurrentSESs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Severely Errored Seconds." ::= { dsx1CurrentEntry 3 } dsx1CurrentSEFSs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Severely Errored Framing Seconds." ::= { dsx1CurrentEntry 4 } dsx1CurrentUASs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current Nicklass, Ed. Standards Track PAGE 37

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 DESCRIPTION "The number of Unavailable Seconds." ::= { dsx1CurrentEntry 5 } dsx1CurrentCSSs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Controlled Slip Seconds." ::= { dsx1CurrentEntry 6 } dsx1CurrentPCVs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Path Coding Violations." ::= { dsx1CurrentEntry 7 } dsx1CurrentLESs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Line Errored Seconds." ::= { dsx1CurrentEntry 8 } dsx1CurrentBESs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Bursty Errored Seconds." ::= { dsx1CurrentEntry 9 } dsx1CurrentDMs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The number of Degraded Minutes." ::= { dsx1CurrentEntry 10 } dsx1CurrentLCVs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current Nicklass, Ed. Standards Track PAGE 38

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 DESCRIPTION "The number of Line Coding Violations (LCVs)." ::= { dsx1CurrentEntry 11 } -- The DS1 Interval Table dsx1IntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx1IntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DS1 Interval table contains various statistics collected by each DS1 interface over the previous 24 hours of operation. The past 24 hours are broken into 96 completed 15-minute intervals. Each row in this table represents one such interval (identified by dsx1IntervalNumber) for one specific instance (identified by dsx1IntervalIndex)." ::= { ds1 8 } dsx1IntervalEntry OBJECT-TYPE SYNTAX Dsx1IntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the DS1 Interval table." INDEX { dsx1IntervalIndex, dsx1IntervalNumber } ::= { dsx1IntervalTable 1 } Dsx1IntervalEntry ::= SEQUENCE { dsx1IntervalIndex InterfaceIndex, dsx1IntervalNumber INTEGER, dsx1IntervalESs PerfIntervalCount, dsx1IntervalSESs PerfIntervalCount, dsx1IntervalSEFSs PerfIntervalCount, dsx1IntervalUASs PerfIntervalCount, dsx1IntervalCSSs PerfIntervalCount, dsx1IntervalPCVs PerfIntervalCount, dsx1IntervalLESs PerfIntervalCount, dsx1IntervalBESs PerfIntervalCount, dsx1IntervalDMs PerfIntervalCount, dsx1IntervalLCVs PerfIntervalCount, dsx1IntervalValidData TruthValue } dsx1IntervalIndex OBJECT-TYPE SYNTAX InterfaceIndex Nicklass, Ed. Standards Track PAGE 39

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 MAX-ACCESS read-only -- read-only since originally an -- SMIv1 index STATUS current DESCRIPTION "The index value that uniquely identifies the DS1 interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value as a dsx1LineIndex object instance." ::= { dsx1IntervalEntry 1 } dsx1IntervalNumber OBJECT-TYPE SYNTAX INTEGER (1..96) MAX-ACCESS read-only -- read-only since originally an -- SMIv1 index STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15-minute interval and 96 is the 15-minute interval completed 23 hours and 45 minutes prior to interval 1." ::= { dsx1IntervalEntry 2 } dsx1IntervalESs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Errored Seconds." ::= { dsx1IntervalEntry 3 } dsx1IntervalSESs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Severely Errored Seconds." ::= { dsx1IntervalEntry 4 } dsx1IntervalSEFSs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Severely Errored Framing Seconds." ::= { dsx1IntervalEntry 5 } dsx1IntervalUASs OBJECT-TYPE Nicklass, Ed. Standards Track PAGE 40

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Unavailable Seconds. This object may decrease if the occurrence of unavailable seconds occurs across an interval boundary." ::= { dsx1IntervalEntry 6 } dsx1IntervalCSSs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Controlled Slip Seconds." ::= { dsx1IntervalEntry 7 } dsx1IntervalPCVs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Path Coding Violations." ::= { dsx1IntervalEntry 8 } dsx1IntervalLESs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Line Errored Seconds." ::= { dsx1IntervalEntry 9 } dsx1IntervalBESs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Bursty Errored Seconds." ::= { dsx1IntervalEntry 10 } dsx1IntervalDMs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The number of Degraded Minutes." ::= { dsx1IntervalEntry 11 } Nicklass, Ed. Standards Track PAGE 41

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 dsx1IntervalLCVs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Line Coding Violations." ::= { dsx1IntervalEntry 12 } dsx1IntervalValidData OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This variable indicates whether the data for this interval is valid." ::= { dsx1IntervalEntry 13 } -- The DS1 Total Table dsx1TotalTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx1TotalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DS1 Total table contains the cumulative sum of the various statistics for the 24-hour period preceding the current interval." ::= { ds1 9 } dsx1TotalEntry OBJECT-TYPE SYNTAX Dsx1TotalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the DS1 Total table." INDEX { dsx1TotalIndex } ::= { dsx1TotalTable 1 } Dsx1TotalEntry ::= SEQUENCE { dsx1TotalIndex InterfaceIndex, dsx1TotalESs PerfTotalCount, dsx1TotalSESs PerfTotalCount, dsx1TotalSEFSs PerfTotalCount, dsx1TotalUASs PerfTotalCount, dsx1TotalCSSs PerfTotalCount, dsx1TotalPCVs PerfTotalCount, dsx1TotalLESs PerfTotalCount, dsx1TotalBESs PerfTotalCount, Nicklass, Ed. Standards Track PAGE 42

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 dsx1TotalDMs PerfTotalCount, dsx1TotalLCVs PerfTotalCount } dsx1TotalIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only -- read-only since originally an -- SMIv1 index STATUS current DESCRIPTION "The index value that uniquely identifies the DS1 interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value as a dsx1LineIndex object instance." ::= { dsx1TotalEntry 1 } dsx1TotalESs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Errored Seconds encountered by a DS1 interface in the previous 24-hour interval. Invalid 15-minute intervals count as 0." ::= { dsx1TotalEntry 2 } dsx1TotalSESs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Severely Errored Seconds encountered by a DS1 interface in the previous 24-hour interval. Invalid 15-minute intervals count as 0." ::= { dsx1TotalEntry 3 } dsx1TotalSEFSs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Severely Errored Framing Seconds encountered by a DS1 interface in the previous 24-hour interval. Invalid 15-minute intervals count as 0." ::= { dsx1TotalEntry 4 } Nicklass, Ed. Standards Track PAGE 43

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 dsx1TotalUASs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Unavailable Seconds encountered by a DS1 interface in the previous 24-hour interval. Invalid 15-minute intervals count as 0." ::= { dsx1TotalEntry 5 } dsx1TotalCSSs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Controlled Slip Seconds encountered by a DS1 interface in the previous 24-hour interval. Invalid 15-minute intervals count as 0." ::= { dsx1TotalEntry 6 } dsx1TotalPCVs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Path Coding Violations encountered by a DS1 interface in the previous 24-hour interval. Invalid 15-minute intervals count as 0." ::= { dsx1TotalEntry 7 } dsx1TotalLESs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Line Errored Seconds encountered by a DS1 interface in the previous 24-hour interval. Invalid 15-minute intervals count as 0." ::= { dsx1TotalEntry 8 } dsx1TotalBESs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Bursty Errored Seconds (BESs) Nicklass, Ed. Standards Track PAGE 44

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 encountered by a DS1 interface in the previous 24-hour interval. Invalid 15-minute intervals count as 0." ::= { dsx1TotalEntry 9 } dsx1TotalDMs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The number of Degraded Minutes (DMs) encountered by a DS1 interface in the previous 24-hour interval. Invalid 15-minute intervals count as 0." ::= { dsx1TotalEntry 10 } dsx1TotalLCVs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Line Coding Violations (LCVs) encountered by a DS1 interface in the current 15-minute interval. Invalid 15-minute intervals count as 0." ::= { dsx1TotalEntry 11 } -- The DS1 Channel Table dsx1ChanMappingTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx1ChanMappingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DS1 Channel Mapping table. This table maps a DS1 channel number on a particular DS3 into an ifIndex. In the presence of DS2s, this table can be used to map a DS2 channel number on a DS3 into an ifIndex, or used to map a DS1 channel number on a DS2 into an ifIndex." ::= { ds1 16 } dsx1ChanMappingEntry OBJECT-TYPE SYNTAX Dsx1ChanMappingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the DS1 Channel Mapping table. There Nicklass, Ed. Standards Track PAGE 45

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 is an entry in this table corresponding to each DS1 ifEntry within any interface that is channelized to the individual DS1 ifEntry level. This table is intended to facilitate mapping from channelized interface / channel number to DS1 ifEntry (e.g., mapping (DS3 ifIndex, DS1 channel number) -> ifIndex). While this table provides information that can also be found in the ifStackTable and dsx1ConfigTable, it provides this same information with a single table lookup, rather than by walking the ifStackTable to find the various constituent DS1 ifTable entries, and testing various dsx1ConfigTable entries to check for the entry with the applicable DS1 channel number." INDEX { ifIndex, dsx1Ds1ChannelNumber } ::= { dsx1ChanMappingTable 1 } Dsx1ChanMappingEntry ::= SEQUENCE { dsx1ChanMappedIfIndex InterfaceIndex } dsx1ChanMappedIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the ifIndex value assigned by the agent for the individual DS1 ifEntry that corresponds to the given DS1 channel number (specified by the INDEX element dsx1Ds1ChannelNumber) of the given channelized interface (specified by INDEX element ifIndex)." ::= { dsx1ChanMappingEntry 1 } -- The DS1 Far End Current Table dsx1FarEndCurrentTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx1FarEndCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DS1 Far End Current table contains various statistics being collected for the current 15-minute interval. The statistics are collected Nicklass, Ed. Standards Track PAGE 46

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 from the far-end messages on the Facilities Data Link. The definitions are the same as described for the near-end information." ::= { ds1 10 } dsx1FarEndCurrentEntry OBJECT-TYPE SYNTAX Dsx1FarEndCurrentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the DS1 Far End Current table." INDEX { dsx1FarEndCurrentIndex } ::= { dsx1FarEndCurrentTable 1 } Dsx1FarEndCurrentEntry ::= SEQUENCE { dsx1FarEndCurrentIndex InterfaceIndex, dsx1FarEndTimeElapsed INTEGER, dsx1FarEndValidIntervals INTEGER, dsx1FarEndCurrentESs PerfCurrentCount, dsx1FarEndCurrentSESs PerfCurrentCount, dsx1FarEndCurrentSEFSs PerfCurrentCount, dsx1FarEndCurrentUASs PerfCurrentCount, dsx1FarEndCurrentCSSs PerfCurrentCount, dsx1FarEndCurrentLESs PerfCurrentCount, dsx1FarEndCurrentPCVs PerfCurrentCount, dsx1FarEndCurrentBESs PerfCurrentCount, dsx1FarEndCurrentDMs PerfCurrentCount, dsx1FarEndInvalidIntervals INTEGER } dsx1FarEndCurrentIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only -- read-only since originally an -- SMIv1 index STATUS current DESCRIPTION "The index value that uniquely identifies the DS1 interface to which this entry is applicable. The interface identified by a particular value of this index is identical to the interface identified by the same value of dsx1LineIndex." ::= { dsx1FarEndCurrentEntry 1 } dsx1FarEndTimeElapsed OBJECT-TYPE SYNTAX INTEGER (0..899) MAX-ACCESS read-only STATUS current Nicklass, Ed. Standards Track PAGE 47

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 DESCRIPTION "The number of seconds that have elapsed since the beginning of the far-end current error-measurement period. If, for some reason, such as an adjustment in the system's time-of-day clock, the current interval exceeds the maximum value, the agent will return the maximum value." ::= { dsx1FarEndCurrentEntry 2 } dsx1FarEndValidIntervals OBJECT-TYPE SYNTAX INTEGER (0..96) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of previous far-end intervals for which data was collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of complete 15-minute far-end intervals since the interface has been online. In the case where the agent is a proxy, it is possible that some intervals are unavailable. In this case, this interval is the maximum interval number for which data is available." ::= { dsx1FarEndCurrentEntry 3 } dsx1FarEndCurrentESs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Far End Errored Seconds." ::= { dsx1FarEndCurrentEntry 4 } dsx1FarEndCurrentSESs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Far End Severely Errored Seconds." ::= { dsx1FarEndCurrentEntry 5 } dsx1FarEndCurrentSEFSs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Far End Severely Errored Framing Nicklass, Ed. Standards Track PAGE 48

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 Seconds." ::= { dsx1FarEndCurrentEntry 6 } dsx1FarEndCurrentUASs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Unavailable Seconds." ::= { dsx1FarEndCurrentEntry 7 } dsx1FarEndCurrentCSSs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Far End Controlled Slip Seconds." ::= { dsx1FarEndCurrentEntry 8 } dsx1FarEndCurrentLESs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Far End Line Errored Seconds." ::= { dsx1FarEndCurrentEntry 9 } dsx1FarEndCurrentPCVs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Far End Path Coding Violations." ::= { dsx1FarEndCurrentEntry 10 } dsx1FarEndCurrentBESs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Far End Bursty Errored Seconds." ::= { dsx1FarEndCurrentEntry 11 } dsx1FarEndCurrentDMs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS deprecated DESCRIPTION Nicklass, Ed. Standards Track PAGE 49

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 "The number of Far End Degraded Minutes." ::= { dsx1FarEndCurrentEntry 12 } dsx1FarEndInvalidIntervals OBJECT-TYPE SYNTAX INTEGER (0..96) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of intervals in the range from 0 to dsx1FarEndValidIntervals for which no data is available. This object will typically be zero except in cases where the data for some intervals is not available (e.g., in proxy situations)." ::= { dsx1FarEndCurrentEntry 13 } -- The DS1 Far End Interval Table dsx1FarEndIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx1FarEndIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DS1 Far End Interval table contains various statistics collected by each DS1 interface over the previous 24 hours of operation. The past 24 hours are broken into 96 completed 15-minute intervals. Each row in this table represents one such interval (identified by dsx1FarEndIntervalNumber) for one specific instance (identified by dsx1FarEndIntervalIndex)." ::= { ds1 11 } dsx1FarEndIntervalEntry OBJECT-TYPE SYNTAX Dsx1FarEndIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the DS1 Far End Interval table." INDEX { dsx1FarEndIntervalIndex, dsx1FarEndIntervalNumber } ::= { dsx1FarEndIntervalTable 1 } Dsx1FarEndIntervalEntry ::= SEQUENCE { dsx1FarEndIntervalIndex InterfaceIndex, dsx1FarEndIntervalNumber INTEGER, dsx1FarEndIntervalESs PerfIntervalCount, dsx1FarEndIntervalSESs PerfIntervalCount, Nicklass, Ed. Standards Track PAGE 50

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 dsx1FarEndIntervalSEFSs PerfIntervalCount, dsx1FarEndIntervalUASs PerfIntervalCount, dsx1FarEndIntervalCSSs PerfIntervalCount, dsx1FarEndIntervalLESs PerfIntervalCount, dsx1FarEndIntervalPCVs PerfIntervalCount, dsx1FarEndIntervalBESs PerfIntervalCount, dsx1FarEndIntervalDMs PerfIntervalCount, dsx1FarEndIntervalValidData TruthValue } dsx1FarEndIntervalIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only -- read-only since originally an -- SMIv1 index STATUS current DESCRIPTION "The index value that uniquely identifies the DS1 interface to which this entry is applicable. The interface identified by a particular value of this index is identical to the interface identified by the same value of dsx1LineIndex." ::= { dsx1FarEndIntervalEntry 1 } dsx1FarEndIntervalNumber OBJECT-TYPE SYNTAX INTEGER (1..96) MAX-ACCESS read-only -- read-only since originally an -- SMIv1 index STATUS current DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15-minute interval and 96 is the 15 minutes interval completed 23 hours and 45 minutes prior to interval 1." ::= { dsx1FarEndIntervalEntry 2 } dsx1FarEndIntervalESs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Far End Errored Seconds." ::= { dsx1FarEndIntervalEntry 3 } dsx1FarEndIntervalSESs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION Nicklass, Ed. Standards Track PAGE 51

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 "The number of Far End Severely Errored Seconds." ::= { dsx1FarEndIntervalEntry 4 } dsx1FarEndIntervalSEFSs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Far End Severely Errored Framing Seconds." ::= { dsx1FarEndIntervalEntry 5 } dsx1FarEndIntervalUASs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Unavailable Seconds." ::= { dsx1FarEndIntervalEntry 6 } dsx1FarEndIntervalCSSs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Far End Controlled Slip Seconds." ::= { dsx1FarEndIntervalEntry 7 } dsx1FarEndIntervalLESs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Far End Line Errored Seconds." ::= { dsx1FarEndIntervalEntry 8 } dsx1FarEndIntervalPCVs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Far End Path Coding Violations." ::= { dsx1FarEndIntervalEntry 9 } dsx1FarEndIntervalBESs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current Nicklass, Ed. Standards Track PAGE 52

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 DESCRIPTION "The number of Far End Bursty Errored Seconds." ::= { dsx1FarEndIntervalEntry 10 } dsx1FarEndIntervalDMs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The number of Far End Degraded Minutes." ::= { dsx1FarEndIntervalEntry 11 } dsx1FarEndIntervalValidData OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION " This variable indicates if the data for this interval is valid." ::= { dsx1FarEndIntervalEntry 12 } -- The DS1 Far End Total Table dsx1FarEndTotalTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx1FarEndTotalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DS1 Far End Total table contains the cumulative sum of the various statistics for the 24-hour period preceding the current interval." ::= { ds1 12 } dsx1FarEndTotalEntry OBJECT-TYPE SYNTAX Dsx1FarEndTotalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the DS1 Far End Total table." INDEX { dsx1FarEndTotalIndex } ::= { dsx1FarEndTotalTable 1 } Dsx1FarEndTotalEntry ::= SEQUENCE { dsx1FarEndTotalIndex InterfaceIndex, dsx1FarEndTotalESs PerfTotalCount, dsx1FarEndTotalSESs PerfTotalCount, dsx1FarEndTotalSEFSs PerfTotalCount, Nicklass, Ed. Standards Track PAGE 53

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 dsx1FarEndTotalUASs PerfTotalCount, dsx1FarEndTotalCSSs PerfTotalCount, dsx1FarEndTotalLESs PerfTotalCount, dsx1FarEndTotalPCVs PerfTotalCount, dsx1FarEndTotalBESs PerfTotalCount, dsx1FarEndTotalDMs PerfTotalCount } dsx1FarEndTotalIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only -- read-only since originally an -- SMIv1 index STATUS current DESCRIPTION "The index value that uniquely identifies the DS1 interface to which this entry is applicable. The interface identified by a particular value of this index is identical to the interface identified by the same value of dsx1LineIndex." ::= { dsx1FarEndTotalEntry 1 } dsx1FarEndTotalESs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Far End Errored Seconds encountered by a DS1 interface in the previous 24-hour interval. Invalid 15-minute intervals count as 0." ::= { dsx1FarEndTotalEntry 2 } dsx1FarEndTotalSESs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Far End Severely Errored Seconds encountered by a DS1 interface in the previous 24-hour interval. Invalid 15-minute intervals count as 0." ::= { dsx1FarEndTotalEntry 3 } dsx1FarEndTotalSEFSs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION Nicklass, Ed. Standards Track PAGE 54

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 "The number of Far End Severely Errored Framing Seconds encountered by a DS1 interface in the previous 24-hour interval. Invalid 15-minute intervals count as 0." ::= { dsx1FarEndTotalEntry 4 } dsx1FarEndTotalUASs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Unavailable Seconds encountered by a DS1 interface in the previous 24-hour interval. Invalid 15-minute intervals count as 0." ::= { dsx1FarEndTotalEntry 5 } dsx1FarEndTotalCSSs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Far End Controlled Slip Seconds encountered by a DS1 interface in the previous 24-hour interval. Invalid 15 minute intervals count as 0." ::= { dsx1FarEndTotalEntry 6 } dsx1FarEndTotalLESs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Far End Line Errored Seconds encountered by a DS1 interface in the previous 24-hour interval. Invalid 15-minute intervals count as 0." ::= { dsx1FarEndTotalEntry 7 } dsx1FarEndTotalPCVs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Far End Path Coding Violations reported via the far end block error count encountered by a DS1 interface in the previous 24-hour interval. Invalid 15-minute intervals count as 0." Nicklass, Ed. Standards Track PAGE 55

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 ::= { dsx1FarEndTotalEntry 8 } dsx1FarEndTotalBESs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Bursty Errored Seconds (BESs) encountered by a DS1 interface in the previous 24-hour interval. Invalid 15-minute intervals count as 0." ::= { dsx1FarEndTotalEntry 9 } dsx1FarEndTotalDMs OBJECT-TYPE SYNTAX PerfTotalCount MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The number of Degraded Minutes (DMs) encountered by a DS1 interface in the previous 24-hour interval. Invalid 15-minute intervals count as 0." ::= { dsx1FarEndTotalEntry 10 } -- The DS1 Fractional Table dsx1FracTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx1FracEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "This table is deprecated in favor of using ifStackTable. The table was mandatory for systems dividing a DS1 into channels containing different data streams that are of local interest. Systems that are indifferent to data content, such as CSUs, need not implement it. The DS1 Fractional table identifies which DS1 channels associated with a CSU are being used to support a logical interface, i.e., an entry in the interfaces table from the Internet-standard MIB. For example, consider an application managing a North American ISDN Primary Rate link whose division is a 384-kbit/s H1 _B_ Channel for video, Nicklass, Ed. Standards Track PAGE 56

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 a second H1 for data to a primary routing peer, and 12 64-kbit/s H0 _B_ Channels. Consider that some subset of the H0 channels is used for voice and the remainder are available for dynamic data calls. We count a total of 14 interfaces multiplexed onto the DS1 interface. Six DS1 channels (for the sake of the example, channels 1..6) are used for video, six more (7..11 and 13) are used for data, and the remaining 12 are in channels 12 and 14..24. Let us further imagine that ifIndex 2 is of type DS1 and refers to the DS1 interface and that the interfaces layered onto it are numbered 3..16. We might describe the allocation of channels, in the dsx1FracTable, as follows: dsx1FracIfIndex.2. 1 = 3 dsx1FracIfIndex.2.13 = 4 dsx1FracIfIndex.2. 2 = 3 dsx1FracIfIndex.2.14 = 6 dsx1FracIfIndex.2. 3 = 3 dsx1FracIfIndex.2.15 = 7 dsx1FracIfIndex.2. 4 = 3 dsx1FracIfIndex.2.16 = 8 dsx1FracIfIndex.2. 5 = 3 dsx1FracIfIndex.2.17 = 9 dsx1FracIfIndex.2. 6 = 3 dsx1FracIfIndex.2.18 = 10 dsx1FracIfIndex.2. 7 = 4 dsx1FracIfIndex.2.19 = 11 dsx1FracIfIndex.2. 8 = 4 dsx1FracIfIndex.2.20 = 12 dsx1FracIfIndex.2. 9 = 4 dsx1FracIfIndex.2.21 = 13 dsx1FracIfIndex.2.10 = 4 dsx1FracIfIndex.2.22 = 14 dsx1FracIfIndex.2.11 = 4 dsx1FracIfIndex.2.23 = 15 dsx1FracIfIndex.2.12 = 5 dsx1FracIfIndex.2.24 = 16 For North American (DS1) interfaces, there are 24 legal channels, numbered 1 through 24. For G.704 interfaces, there are 31 legal channels, numbered 1 through 31. The channels (1..31) correspond directly to the equivalently numbered time-slots." ::= { ds1 13 } dsx1FracEntry OBJECT-TYPE SYNTAX Dsx1FracEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "An entry in the DS1 Fractional table." INDEX { dsx1FracIndex, dsx1FracNumber } ::= { dsx1FracTable 1 } Nicklass, Ed. Standards Track PAGE 57

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 Dsx1FracEntry ::= SEQUENCE { dsx1FracIndex INTEGER, dsx1FracNumber INTEGER, dsx1FracIfIndex INTEGER } dsx1FracIndex OBJECT-TYPE SYNTAX INTEGER (1..'7fffffff'h) MAX-ACCESS read-only -- read-only since originally an -- SMIv1 index STATUS deprecated DESCRIPTION "The index value that uniquely identifies the DS1 interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value as a dsx1LineIndex object instance." ::= { dsx1FracEntry 1 } dsx1FracNumber OBJECT-TYPE SYNTAX INTEGER (1..31) MAX-ACCESS read-only -- read-only since originally an -- SMIv1 index STATUS deprecated DESCRIPTION "The channel number for this entry." ::= { dsx1FracEntry 2 } dsx1FracIfIndex OBJECT-TYPE SYNTAX INTEGER (0..'7fffffff'h) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "An index value that uniquely identifies an interface. The interface identified by a particular value of this index is the same interface as identified by the same value as an ifIndex object instance. If no interface is currently using a channel, the value should be zero. If a single interface occupies more than one time-slot, that ifIndex value will be found in multiple time-slots." ::= { dsx1FracEntry 3 } -- DS1 TRAPS Nicklass, Ed. Standards Track PAGE 58

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 ds1Traps OBJECT IDENTIFIER ::= { ds1 15 } dsx1LineStatusChange NOTIFICATION-TYPE OBJECTS { dsx1LineStatus, dsx1LineStatusLastChange } STATUS current DESCRIPTION "A dsx1LineStatusChange trap is sent when the value of an instance dsx1LineStatus changes. It can be utilized by an Network Management Station (NMS) to trigger polls. When the line status change results from a higher-level line status change (i.e., DS3), then no traps for the DS1 are sent." ::= { ds1Traps 0 1 } -- conformance information ds1Conformance OBJECT IDENTIFIER ::= { ds1 14 } ds1Groups OBJECT IDENTIFIER ::= { ds1Conformance 1 } ds1Compliances OBJECT IDENTIFIER ::= { ds1Conformance 2 } -- compliance statements ds1Compliance MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for T1 and E1 interfaces." MODULE -- this module MANDATORY-GROUPS { ds1NearEndConfigGroup, ds1NearEndStatisticsGroup } GROUP ds1FarEndGroup DESCRIPTION "Implementation of this group is optional for all systems that attach to a DS1 interface." GROUP ds1NearEndOptionalConfigGroup DESCRIPTION "Implementation of this group is optional for all systems that attach to a DS1 interface." GROUP ds1DS2Group DESCRIPTION "Implementation of this group is mandatory for all systems that attach to a DS2 interface." Nicklass, Ed. Standards Track PAGE 59

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 GROUP ds1TransStatsGroup DESCRIPTION "This group is the set of statistics appropriate for all systems that attach to a DS1 interface running transparent or unFramed lineType." GROUP ds1ChanMappingGroup DESCRIPTION "This group is the set of objects for mapping a DS3 Channel (dsx1Ds1ChannelNumber) to ifIndex. Implementation of this group is mandatory for systems that support the channelization of DS3s into DS1s." OBJECT dsx1LineType SYNTAX INTEGER { other(1), dsx1ESF(2), dsx1D4(3), dsx1E1(4), dsx1E1CRC(5), dsx1E1MF(6), dsx1E1CRCMF(7), dsx1Unframed(8), dsx1E1Unframed(9), dsx1DS2M12(10), dsx1E2(11) } MIN-ACCESS read-only DESCRIPTION "The ability to set the line type is not required." OBJECT dsx1LineCoding MIN-ACCESS read-only DESCRIPTION "The ability to set the line coding is not required." OBJECT dsx1SendCode MIN-ACCESS read-only DESCRIPTION "The ability to set the send code is not required." OBJECT dsx1LoopbackConfig MIN-ACCESS read-only DESCRIPTION Nicklass, Ed. Standards Track PAGE 60

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 "The ability to set loopbacks is not required." OBJECT dsx1SignalMode MIN-ACCESS read-only DESCRIPTION "The ability to set the signal mode is not required." OBJECT dsx1TransmitClockSource SYNTAX INTEGER { loopTiming(1), localTiming(2), throughTiming(3) } MIN-ACCESS read-only DESCRIPTION "The ability to set the transmit clock source is not required." OBJECT dsx1Fdl MIN-ACCESS read-only DESCRIPTION "The ability to set the FDL is not required." OBJECT dsx1LineLength MIN-ACCESS read-only DESCRIPTION "The ability to set the line length is not required." OBJECT dsx1Channelization MIN-ACCESS read-only DESCRIPTION "The ability to set the channelization is not required." ::= { ds1Compliances 1 } ds1MibT1PriCompliance MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "Compliance statement for using this MIB for ISDN Primary Rate interfaces on T1 lines." MODULE MANDATORY-GROUPS { ds1NearEndConfigGroup, ds1NearEndStatisticsGroup } OBJECT dsx1LineType SYNTAX INTEGER { dsx1ESF(2) -- Intl Spec would be G704(2) Nicklass, Ed. Standards Track PAGE 61

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 -- or I.431(4) } MIN-ACCESS read-only DESCRIPTION "Line type for T1 ISDN Primary Rate interfaces." OBJECT dsx1LineCoding SYNTAX INTEGER { dsx1B8ZS(2) } MIN-ACCESS read-only DESCRIPTION "Type of Zero Code Suppression for T1 ISDN Primary Rate interfaces." OBJECT dsx1SignalMode SYNTAX INTEGER { none(1), -- if there is no signaling channel messageOriented(4) } MIN-ACCESS read-only DESCRIPTION "Possible signaling modes for T1 ISDN Primary Rate interfaces." OBJECT dsx1TransmitClockSource SYNTAX INTEGER { loopTiming(1) } MIN-ACCESS read-only DESCRIPTION "The transmit clock is derived from received clock on ISDN Primary Rate interfaces." OBJECT dsx1Fdl MIN-ACCESS read-only DESCRIPTION "Facilities Data Link usage on T1 ISDN Primary Rate interfaces. Note: Eventually, dsx1Att-54016(4) is to be used here since the line type is ESF." OBJECT dsx1Channelization MIN-ACCESS read-only DESCRIPTION "The ability to set the channelization Nicklass, Ed. Standards Track PAGE 62

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 is not required." ::= { ds1Compliances 2 } ds1MibE1PriCompliance MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "Compliance statement for using this MIB for ISDN Primary Rate interfaces on E1 lines." MODULE MANDATORY-GROUPS { ds1NearEndConfigGroup, ds1NearEndStatisticsGroup } OBJECT dsx1LineType SYNTAX INTEGER { dsx1E1CRC(5) } MIN-ACCESS read-only DESCRIPTION "Line type for E1 ISDN Primary Rate interfaces." OBJECT dsx1LineCoding SYNTAX INTEGER { dsx1HDB3(3) } MIN-ACCESS read-only DESCRIPTION "Type of Zero Code Suppression for E1 ISDN Primary Rate interfaces." OBJECT dsx1SignalMode SYNTAX INTEGER { messageOriented(4) } MIN-ACCESS read-only DESCRIPTION "Signaling on E1 ISDN Primary Rate interfaces is always message oriented." OBJECT dsx1TransmitClockSource SYNTAX INTEGER { loopTiming(1) } MIN-ACCESS read-only DESCRIPTION "The transmit clock is derived from received clock on ISDN Primary Rate interfaces." OBJECT dsx1Fdl Nicklass, Ed. Standards Track PAGE 63

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 MIN-ACCESS read-only DESCRIPTION "Facilities Data Link usage on E1 ISDN Primary Rate interfaces. Note: There is an 'M-Channel' in E1, using National Bit Sa4 (G.704, Table 5A). It is used to implement management features between ET and NT. This is different from FDL in T1, which is used to carry control signals and performance data. In E1, control and status signals are carried using National Bits Sa5, Sa6, and A (RAI Ind.). This indicates that only the other(1) or eventually the dsx1Fdl-none(8) bits should be set in this object for E1 PRI." OBJECT dsx1Channelization MIN-ACCESS read-only DESCRIPTION "The ability to set the channelization is not required." ::= { ds1Compliances 3 } ds1Ds2Compliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Compliance statement for using this MIB for DS2 interfaces." MODULE MANDATORY-GROUPS { ds1DS2Group } OBJECT dsx1LineType SYNTAX INTEGER { dsx1DS2M12(10), dsx1E2(11) } MIN-ACCESS read-only DESCRIPTION "Line type for DS2, E2 interfaces." OBJECT dsx1Channelization MIN-ACCESS read-only DESCRIPTION "The ability to set the channelization is not required." Nicklass, Ed. Standards Track PAGE 64

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 ::= { ds1Compliances 4 } ds1NCompliance MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for T1 and E1 interfaces." MODULE -- this module MANDATORY-GROUPS { ds1NearEndConfigurationGroup, ds1NearEndStatisticsGroup } GROUP ds1FarEndGroup DESCRIPTION "Implementation of this group is optional for all systems that attach to a DS1 interface." GROUP ds1NearEndOptionalTrapGroup DESCRIPTION "Implementation of this group is optional for all systems that attach to a DS1 interface. If it is implemented, then ds1NearEndOptionalConfigGroup should also be implemented." GROUP ds1NearEndOptionalConfigGroup DESCRIPTION "Implementation of this group is recommended for all systems that attach to a DS1 interface and implement ds1NearEndOptionalTrapGroup." GROUP ds1DS2Group DESCRIPTION "Implementation of this group is mandatory for all systems that attach to a DS2 interface." GROUP ds1TransStatsGroup DESCRIPTION "This group is the set of statistics appropriate for all systems that attach to a DS1 interface running transparent or unFramed lineType." GROUP ds1ChanMappingGroup DESCRIPTION "This group is the set of objects for mapping a DS3 Channel (dsx1Ds1ChannelNumber) to ifIndex. Implementation of this group is mandatory for systems that support the channelization of DS3s into DS1s." Nicklass, Ed. Standards Track PAGE 65

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 OBJECT dsx1LineType MIN-ACCESS read-only DESCRIPTION "The ability to set the line type is not required." OBJECT dsx1LineCoding MIN-ACCESS read-only DESCRIPTION "The ability to set the line coding is not required." OBJECT dsx1SendCode MIN-ACCESS read-only DESCRIPTION "The ability to set the send code is not required." OBJECT dsx1LoopbackConfig MIN-ACCESS read-only DESCRIPTION "The ability to set loopbacks is not required." OBJECT dsx1SignalMode MIN-ACCESS read-only DESCRIPTION "The ability to set the signal mode is not required." OBJECT dsx1TransmitClockSource MIN-ACCESS read-only DESCRIPTION "The ability to set the transmit clock source is not required." OBJECT dsx1Fdl MIN-ACCESS read-only DESCRIPTION "The ability to set the FDL is not required." OBJECT dsx1LineLength MIN-ACCESS read-only DESCRIPTION "The ability to set the line length is not required." OBJECT dsx1Channelization MIN-ACCESS read-only Nicklass, Ed. Standards Track PAGE 66

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 DESCRIPTION "The ability to set the channelization is not required." OBJECT dsx1LineMode MIN-ACCESS read-only DESCRIPTION "The ability to set the line mode is not required." OBJECT dsx1LineBuildOut MIN-ACCESS read-only DESCRIPTION "The ability to set the line build-out is not required." ::= { ds1Compliances 5 } ds1MibT1PriNCompliance MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "Compliance statement for using this MIB for ISDN Primary Rate interfaces on T1 lines." MODULE MANDATORY-GROUPS { ds1NearEndConfigurationGroup, ds1NearEndStatisticsGroup } OBJECT dsx1LineType SYNTAX INTEGER { dsx1ESF(2) -- Intl Spec would be G704(2) -- or I.431(4) } MIN-ACCESS read-only DESCRIPTION "Line type for T1 ISDN Primary Rate interfaces." OBJECT dsx1LineCoding SYNTAX INTEGER { dsx1B8ZS(2) } MIN-ACCESS read-only DESCRIPTION "Type of Zero Code Suppression for T1 ISDN Primary Rate interfaces." OBJECT dsx1SignalMode SYNTAX INTEGER { none(1), -- if there is no signaling channel messageOriented(4) Nicklass, Ed. Standards Track PAGE 67

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 } MIN-ACCESS read-only DESCRIPTION "Possible signaling modes for T1 ISDN Primary Rate interfaces." OBJECT dsx1TransmitClockSource SYNTAX INTEGER { loopTiming(1) } MIN-ACCESS read-only DESCRIPTION "The transmit clock is derived from received clock on ISDN Primary Rate interfaces." OBJECT dsx1Fdl MIN-ACCESS read-only DESCRIPTION "Facilities Data Link usage on T1 ISDN Primary Rate interfaces. Note: Eventually, dsx1Att-54016(4) is to be used here since the line type is ESF." OBJECT dsx1Channelization MIN-ACCESS read-only DESCRIPTION "The ability to set the channelization is not required." OBJECT dsx1LineMode MIN-ACCESS read-only DESCRIPTION "The ability to set the line mode is not required." OBJECT dsx1LineBuildOut MIN-ACCESS read-only DESCRIPTION "The ability to set the line build-out is not required." ::= { ds1Compliances 6 } ds1MibE1PriNCompliance MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "Compliance statement for using this MIB for ISDN Primary Rate interfaces on E1 lines." Nicklass, Ed. Standards Track PAGE 68

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 MODULE MANDATORY-GROUPS { ds1NearEndConfigurationGroup, ds1NearEndStatisticsGroup } OBJECT dsx1LineType SYNTAX INTEGER { dsx1E1CRC(5) } MIN-ACCESS read-only DESCRIPTION "Line type for E1 ISDN Primary Rate interfaces." OBJECT dsx1LineCoding SYNTAX INTEGER { dsx1HDB3(3) } MIN-ACCESS read-only DESCRIPTION "Type of Zero Code Suppression for E1 ISDN Primary Rate interfaces." OBJECT dsx1SignalMode SYNTAX INTEGER { messageOriented(4) } MIN-ACCESS read-only DESCRIPTION "Signaling on E1 ISDN Primary Rate interfaces is always message oriented." OBJECT dsx1TransmitClockSource SYNTAX INTEGER { loopTiming(1) } MIN-ACCESS read-only DESCRIPTION "The transmit clock is derived from received clock on ISDN Primary Rate interfaces." OBJECT dsx1Fdl MIN-ACCESS read-only DESCRIPTION "Facilities Data Link usage on E1 ISDN Primary Rate interfaces. Note: There is an 'M-Channel' in E1, using National Bit Sa4 (G704, Table 5A). It is used to implement Nicklass, Ed. Standards Track PAGE 69

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 management features between ET and NT. This is different from FDL in T1, which is used to carry control signals and performance data. In E1, control and status signals are carried using National Bits Sa5, Sa6, and A (RAI Ind.). This indicates that only the other(1) or eventually the dsx1Fdl-none(8) bits should be set in this object for E1 PRI." OBJECT dsx1Channelization MIN-ACCESS read-only DESCRIPTION "The ability to set the channelization is not required." OBJECT dsx1LineMode MIN-ACCESS read-only DESCRIPTION "The ability to set the line mode is not required." OBJECT dsx1LineBuildOut MIN-ACCESS read-only DESCRIPTION "The ability to set the line build-out is not required." ::= { ds1Compliances 7 } ds1J1Compliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for T1, J1, and E1 interfaces." MODULE -- this module MANDATORY-GROUPS { ds1NearEndCfgGroup, ds1NearEndStatGroup } GROUP ds1FarEndNGroup DESCRIPTION "Implementation of this group is optional for all systems that attach to a DS1 interface." GROUP ds1NearEndOptionalTrapGroup DESCRIPTION "Implementation of this group is optional for all systems that attach to a DS1 interface. If it is Nicklass, Ed. Standards Track PAGE 70

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 implemented, then ds1NearEndOptionalConfigGroup should also be implemented." GROUP ds1NearEndOptionalConfigGroup DESCRIPTION "Implementation of this group is recommended for all systems that attach to a DS1 interface and implement ds1NearEndOptionalTrapGroup." GROUP ds1DS2Group DESCRIPTION "Implementation of this group is mandatory for all systems that attach to a DS2 interface." GROUP ds1TransStatsGroup DESCRIPTION "This group is the set of statistics appropriate for all systems that attach to a DS1 interface running transparent or unFramed lineType." GROUP ds1ChanMappingGroup DESCRIPTION "This group is the set of objects for mapping a DS3 Channel (dsx1Ds1ChannelNumber) to ifIndex. Implementation of this group is mandatory for systems that support the channelization of DS3s into DS1s." OBJECT dsx1LineType MIN-ACCESS read-only DESCRIPTION "The ability to set the line type is not required." OBJECT dsx1LineCoding MIN-ACCESS read-only DESCRIPTION "The ability to set the line coding is not required." OBJECT dsx1SendCode MIN-ACCESS read-only DESCRIPTION "The ability to set the send code is not required." OBJECT dsx1LoopbackConfig MIN-ACCESS read-only Nicklass, Ed. Standards Track PAGE 71

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 DESCRIPTION "The ability to set loopbacks is not required." OBJECT dsx1SignalMode MIN-ACCESS read-only DESCRIPTION "The ability to set the signal mode is not required." OBJECT dsx1TransmitClockSource MIN-ACCESS read-only DESCRIPTION "The ability to set the transmit clock source is not required." OBJECT dsx1Fdl MIN-ACCESS read-only DESCRIPTION "The ability to set the FDL is not required." OBJECT dsx1LineLength MIN-ACCESS read-only DESCRIPTION "The ability to set the line length is not required." OBJECT dsx1Channelization MIN-ACCESS read-only DESCRIPTION "The ability to set the channelization is not required." OBJECT dsx1LineMode MIN-ACCESS read-only DESCRIPTION "The ability to set the line mode is not required." OBJECT dsx1LineBuildOut MIN-ACCESS read-only DESCRIPTION "The ability to set the line build-out is not required." OBJECT dsx1LineImpedance MIN-ACCESS read-only DESCRIPTION "The ability to set line impedance is not Nicklass, Ed. Standards Track PAGE 72

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 required." ::= { ds1Compliances 8 } ds1NMibT1PriNCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Compliance statement for using this MIB for ISDN Primary Rate interfaces on T1 lines." MODULE MANDATORY-GROUPS { ds1NearEndCfgGroup, ds1NearEndStatGroup } OBJECT dsx1LineType SYNTAX INTEGER { dsx1ESF(2) -- Intl Spec would be G704(2) -- or I.431(4) } MIN-ACCESS read-only DESCRIPTION "Line type for T1 ISDN Primary Rate interfaces." OBJECT dsx1LineCoding SYNTAX INTEGER { dsx1B8ZS(2) } MIN-ACCESS read-only DESCRIPTION "Type of Zero Code Suppression for T1 ISDN Primary Rate interfaces." OBJECT dsx1SignalMode SYNTAX INTEGER { none(1), -- if there is no signaling channel messageOriented(4) } MIN-ACCESS read-only DESCRIPTION "Possible signaling modes for T1 ISDN Primary Rate interfaces." OBJECT dsx1TransmitClockSource SYNTAX INTEGER { loopTiming(1) } MIN-ACCESS read-only DESCRIPTION "The transmit clock is derived from received clock on ISDN Primary Rate Nicklass, Ed. Standards Track PAGE 73

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 interfaces." OBJECT dsx1Fdl MIN-ACCESS read-only DESCRIPTION "Facilities Data Link usage on T1 ISDN Primary Rate interfaces. Note: Eventually, dsx1Att-54016(4) is to be used here since the line type is ESF." OBJECT dsx1Channelization MIN-ACCESS read-only DESCRIPTION "The ability to set the channelization is not required." OBJECT dsx1LineMode MIN-ACCESS read-only DESCRIPTION "The ability to set the line mode is not required." OBJECT dsx1LineBuildOut MIN-ACCESS read-only DESCRIPTION "The ability to set the line build-out is not required." ::= { ds1Compliances 9 } ds1NMibE1PriNCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Compliance statement for using this MIB for ISDN Primary Rate interfaces on E1 lines." MODULE MANDATORY-GROUPS { ds1NearEndCfgGroup, ds1NearEndStatGroup } OBJECT dsx1LineType SYNTAX INTEGER { dsx1E1CRC(5) } MIN-ACCESS read-only DESCRIPTION "Line type for E1 ISDN Primary Rate interfaces." OBJECT dsx1LineCoding Nicklass, Ed. Standards Track PAGE 74

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 SYNTAX INTEGER { dsx1HDB3(3) } MIN-ACCESS read-only DESCRIPTION "Type of Zero Code Suppression for E1 ISDN Primary Rate interfaces." OBJECT dsx1SignalMode SYNTAX INTEGER { messageOriented(4) } MIN-ACCESS read-only DESCRIPTION "Signaling on E1 ISDN Primary Rate interfaces is always message oriented." OBJECT dsx1TransmitClockSource SYNTAX INTEGER { loopTiming(1) } MIN-ACCESS read-only DESCRIPTION "The transmit clock is derived from received clock on ISDN Primary Rate interfaces." OBJECT dsx1Fdl MIN-ACCESS read-only DESCRIPTION "Facilities Data Link usage on E1 ISDN Primary Rate interfaces. Note: There is an 'M-Channel' in E1, using National Bit Sa4 (G704, Table 5A). It is used to implement management features between ET and NT. This is different from FDL in T1, which is used to carry control signals and performance data. In E1, control and status signals are carried using National Bits Sa5, Sa6, and A (RAI Ind.). This indicates that only the other(1) or eventually the dsx1Fdl-none(8) bits should be set in this object for E1 PRI." OBJECT dsx1Channelization MIN-ACCESS read-only DESCRIPTION Nicklass, Ed. Standards Track PAGE 75

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 "The ability to set the channelization is not required." OBJECT dsx1LineMode MIN-ACCESS read-only DESCRIPTION "The ability to set the line mode is not required." OBJECT dsx1LineBuildOut MIN-ACCESS read-only DESCRIPTION "The ability to set the line build-out is not required." OBJECT dsx1LineImpedance MIN-ACCESS read-only DESCRIPTION "The ability to set line impedance is not required." ::= { ds1Compliances 10 } -- units of conformance ds1NearEndConfigGroup OBJECT-GROUP OBJECTS { dsx1LineIndex, dsx1TimeElapsed, dsx1ValidIntervals, dsx1LineType, dsx1LineCoding, dsx1SendCode, dsx1CircuitIdentifier, dsx1LoopbackConfig, dsx1LineStatus, dsx1SignalMode, dsx1TransmitClockSource, dsx1Fdl, dsx1InvalidIntervals, dsx1LineLength, dsx1LoopbackStatus, dsx1Ds1ChannelNumber, dsx1Channelization } STATUS deprecated DESCRIPTION "A collection of objects providing configuration information applicable to all DS1 interfaces." ::= { ds1Groups 1 } Nicklass, Ed. Standards Track PAGE 76

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 ds1NearEndStatisticsGroup OBJECT-GROUP OBJECTS { dsx1CurrentIndex, dsx1CurrentESs, dsx1CurrentSESs, dsx1CurrentSEFSs, dsx1CurrentUASs, dsx1CurrentCSSs, dsx1CurrentPCVs, dsx1CurrentLESs, dsx1CurrentBESs, dsx1CurrentDMs, dsx1CurrentLCVs, dsx1IntervalIndex, dsx1IntervalNumber, dsx1IntervalESs, dsx1IntervalSESs, dsx1IntervalSEFSs, dsx1IntervalUASs, dsx1IntervalCSSs, dsx1IntervalPCVs, dsx1IntervalLESs, dsx1IntervalBESs, dsx1IntervalDMs, dsx1IntervalLCVs, dsx1IntervalValidData, dsx1TotalIndex, dsx1TotalESs, dsx1TotalSESs, dsx1TotalSEFSs, dsx1TotalUASs, dsx1TotalCSSs, dsx1TotalPCVs, dsx1TotalLESs, dsx1TotalBESs, dsx1TotalDMs, dsx1TotalLCVs } STATUS deprecated DESCRIPTION "A collection of objects providing statistics information applicable to all DS1 interfaces." ::= { ds1Groups 2 } ds1FarEndGroup OBJECT-GROUP OBJECTS { dsx1FarEndCurrentIndex, dsx1FarEndTimeElapsed, dsx1FarEndValidIntervals, dsx1FarEndCurrentESs, dsx1FarEndCurrentSESs, Nicklass, Ed. Standards Track PAGE 77

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 dsx1FarEndCurrentSEFSs, dsx1FarEndCurrentUASs, dsx1FarEndCurrentCSSs, dsx1FarEndCurrentLESs, dsx1FarEndCurrentPCVs, dsx1FarEndCurrentBESs, dsx1FarEndCurrentDMs, dsx1FarEndInvalidIntervals, dsx1FarEndIntervalIndex, dsx1FarEndIntervalNumber, dsx1FarEndIntervalESs, dsx1FarEndIntervalSESs, dsx1FarEndIntervalSEFSs, dsx1FarEndIntervalUASs, dsx1FarEndIntervalCSSs, dsx1FarEndIntervalLESs, dsx1FarEndIntervalPCVs, dsx1FarEndIntervalBESs, dsx1FarEndIntervalDMs, dsx1FarEndIntervalValidData, dsx1FarEndTotalIndex, dsx1FarEndTotalESs, dsx1FarEndTotalSESs, dsx1FarEndTotalSEFSs, dsx1FarEndTotalUASs, dsx1FarEndTotalCSSs, dsx1FarEndTotalLESs, dsx1FarEndTotalPCVs, dsx1FarEndTotalBESs, dsx1FarEndTotalDMs } STATUS deprecated DESCRIPTION "A collection of objects providing remote configuration and statistics information." ::= { ds1Groups 3 } ds1DeprecatedGroup OBJECT-GROUP OBJECTS { dsx1IfIndex, dsx1FracIndex, dsx1FracNumber, dsx1FracIfIndex } STATUS deprecated DESCRIPTION "A collection of obsolete objects that may be implemented for backwards compatibility." ::= { ds1Groups 4 } ds1NearEndOptionalConfigGroup OBJECT-GROUP Nicklass, Ed. Standards Track PAGE 78

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 OBJECTS { dsx1LineStatusLastChange, dsx1LineStatusChangeTrapEnable } STATUS current DESCRIPTION "A collection of objects that may be implemented on DS1 and DS2 interfaces." ::= { ds1Groups 5 } ds1DS2Group OBJECT-GROUP OBJECTS { dsx1LineIndex, dsx1LineType, dsx1LineCoding, dsx1SendCode, dsx1LineStatus, dsx1SignalMode, dsx1TransmitClockSource, dsx1Channelization } STATUS current DESCRIPTION "A collection of objects providing information about DS2 (6,312 kbps) and E2 (8,448 kbps) systems." ::= { ds1Groups 6 } ds1TransStatsGroup OBJECT-GROUP OBJECTS { dsx1CurrentESs, dsx1CurrentSESs, dsx1CurrentUASs, dsx1IntervalESs, dsx1IntervalSESs, dsx1IntervalUASs, dsx1TotalESs, dsx1TotalSESs, dsx1TotalUASs } STATUS current DESCRIPTION "A collection of objects that are the statistics that can be collected from a DS1 interface that is running transparent or unframed lineType. Statistics not in this list should return noSuchInstance." ::= { ds1Groups 7 } ds1NearEndOptionalTrapGroup NOTIFICATION-GROUP NOTIFICATIONS { dsx1LineStatusChange } STATUS current DESCRIPTION Nicklass, Ed. Standards Track PAGE 79

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 "A collection of notifications that may be implemented on DS1 and DS2 interfaces." ::= { ds1Groups 8 } ds1ChanMappingGroup OBJECT-GROUP OBJECTS { dsx1ChanMappedIfIndex } STATUS current DESCRIPTION "A collection of objects that give a mapping of DS3 Channel (dsx1Ds1ChannelNumber) to ifIndex." ::= { ds1Groups 9 } ds1NearEndConfigurationGroup OBJECT-GROUP OBJECTS { dsx1LineIndex, dsx1TimeElapsed, dsx1ValidIntervals, dsx1LineType, dsx1LineCoding, dsx1SendCode, dsx1CircuitIdentifier, dsx1LoopbackConfig, dsx1LineStatus, dsx1SignalMode, dsx1TransmitClockSource, dsx1Fdl, dsx1InvalidIntervals, dsx1LineLength, dsx1LoopbackStatus, dsx1Ds1ChannelNumber, dsx1Channelization, dsx1LineMode, dsx1LineBuildOut } STATUS deprecated DESCRIPTION "A collection of objects providing configuration information applicable to all DS1 interfaces." ::= { ds1Groups 10 } ds1NearEndCfgGroup OBJECT-GROUP OBJECTS { dsx1LineIndex, dsx1TimeElapsed, dsx1ValidIntervals, dsx1LineType, dsx1LineCoding, dsx1SendCode, dsx1CircuitIdentifier, dsx1LoopbackConfig, dsx1LineStatus, Nicklass, Ed. Standards Track PAGE 80

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 dsx1SignalMode, dsx1TransmitClockSource, dsx1Fdl, dsx1InvalidIntervals, dsx1LineLength, dsx1LoopbackStatus, dsx1Ds1ChannelNumber, dsx1Channelization, dsx1LineMode, dsx1LineBuildOut, dsx1LineImpedance } STATUS current DESCRIPTION "A collection of objects providing configuration information applicable to all DS1 interfaces." ::= { ds1Groups 11 } ds1NearEndStatGroup OBJECT-GROUP OBJECTS { dsx1CurrentIndex, dsx1CurrentESs, dsx1CurrentSESs, dsx1CurrentSEFSs, dsx1CurrentUASs, dsx1CurrentCSSs, dsx1CurrentPCVs, dsx1CurrentLESs, dsx1CurrentBESs, dsx1CurrentLCVs, dsx1IntervalIndex, dsx1IntervalNumber, dsx1IntervalESs, dsx1IntervalSESs, dsx1IntervalSEFSs, dsx1IntervalUASs, dsx1IntervalCSSs, dsx1IntervalPCVs, dsx1IntervalLESs, dsx1IntervalBESs, dsx1IntervalLCVs, dsx1IntervalValidData, dsx1TotalIndex, dsx1TotalESs, dsx1TotalSESs, dsx1TotalSEFSs, dsx1TotalUASs, dsx1TotalCSSs, dsx1TotalPCVs, dsx1TotalLESs, Nicklass, Ed. Standards Track PAGE 81

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 dsx1TotalBESs, dsx1TotalLCVs } STATUS current DESCRIPTION "A collection of objects providing statistics information applicable to all DS1 interfaces." ::= { ds1Groups 12 } ds1FarEndNGroup OBJECT-GROUP OBJECTS { dsx1FarEndCurrentIndex, dsx1FarEndTimeElapsed, dsx1FarEndValidIntervals, dsx1FarEndCurrentESs, dsx1FarEndCurrentSESs, dsx1FarEndCurrentSEFSs, dsx1FarEndCurrentUASs, dsx1FarEndCurrentCSSs, dsx1FarEndCurrentLESs, dsx1FarEndCurrentPCVs, dsx1FarEndCurrentBESs, dsx1FarEndInvalidIntervals, dsx1FarEndIntervalIndex, dsx1FarEndIntervalNumber, dsx1FarEndIntervalESs, dsx1FarEndIntervalSESs, dsx1FarEndIntervalSEFSs, dsx1FarEndIntervalUASs, dsx1FarEndIntervalCSSs, dsx1FarEndIntervalLESs, dsx1FarEndIntervalPCVs, dsx1FarEndIntervalBESs, dsx1FarEndIntervalValidData, dsx1FarEndTotalIndex, dsx1FarEndTotalESs, dsx1FarEndTotalSESs, dsx1FarEndTotalSEFSs, dsx1FarEndTotalUASs, dsx1FarEndTotalCSSs, dsx1FarEndTotalLESs, dsx1FarEndTotalPCVs, dsx1FarEndTotalBESs} STATUS current DESCRIPTION "A collection of objects providing remote configuration and statistics information." ::= { ds1Groups 13 } END Nicklass, Ed. Standards Track PAGE 82

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 5. Security Considerations There are a number of management objects defined in this MIB module with a MAX-ACCESS clause of read-write. Such objects may be considered sensitive or vulnerable in some network environments. The support for SET operations in a non-secure environment without proper protection can have a negative effect on network operations. The specific objects and their sensitivities/vulnerabilities are as follows. Setting the following objects to incorrect values may result in traffic interruptions: dsx1LineType dsx1LineCoding dsx1SendCode dsx1LoopbackConfig dsx1SignalMode dsx1TransmitClockSource dsx1Fdl dsx1LineLength dsx1Channelization dsx1LineMode dsx1LineBuildOut dsx1LineImpedance In the case of dsx1LineType, for example, both ends of a DS1/E1 must have the same value in order for traffic to flow. In the case of dsx1SendCode and dsx1LoopbackConfig, for another example, traffic may stop transmitting when particular loopbacks are applied. Setting the following object to an incorrect value will not harm the traffic, but it may cause a circuit to be misidentified and thereby create difficulties for service personnel when attempting to troubleshoot a problem: dsx1CircuitIdentifier Setting the following object can cause an increase in the number of traps received by the network management station: dsx1LineStatusChangeTrapEnable The readable objects in this MIB module (i.e., the objects with a MAX-ACCESS other than not-accessible) may be considered sensitive in some environments since, collectively, they provide extensive information about the performance of interfaces in DS1/J1/E1/DS2/E2 equipment or networks and can reveal some aspects of their Nicklass, Ed. Standards Track PAGE 83

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 configuration. In such environments, it is important to control even GET and NOTIFY access to these objects and possibly to encrypt the values of these objects when sending them over the network via SNMP. SNMP versions prior to SNMPv3 did not include adequate security. Even if the network itself is secure (for example by using IPSec), even then, there is no control as to who on the secure network is allowed to access and GET/SET (read/change/create/delete) the objects in this MIB module. It is RECOMMENDED that implementers consider the security features as provided by the SNMPv3 framework (see [RFC 3410], section 8), including full support for the SNMPv3 cryptographic mechanisms (for authentication and privacy). Further, deployment of SNMP versions prior to SNMPv3 is NOT RECOMMENDED. Instead, it is RECOMMENDED to deploy SNMPv3 and to enable cryptographic security. It is then a customer/operator responsibility to ensure that the SNMP entity giving access to an instance of this MIB module is properly configured to give access to the objects only to those principals (users) that have legitimate rights to indeed GET or SET (change/create/delete) them. 6. Acknowledgments This document was produced by the AToM MIB Working Group. 7. References 7.1. Normative References [RFC 2119] Bradner, S., "Key words for use in RFCs to Indicate Requirement Levels", BCP 14, RFC 2119, March 1997. [RFC 2578] McCloghrie, K., Perkins, D., and J. Schoenwaelder, "Structure of Management Information Version 2 (SMIv2)", STD 58, RFC 2578, April 1999. [RFC 2579] McCloghrie, K., Perkins, D., and J. Schoenwaelder, "Textual Conventions for SMIv2", STD 58, RFC 2579, April 1999. [RFC 2580] McCloghrie, K., Perkins, D., and J. Schoenwaelder, "Conformance Statements for SMIv2", STD 58, RFC 2580, April 1999. [RFC 2863] McCloghrie, K. and F. Kastenholz, "The Interfaces Group MIB", RFC 2863, June 2000. Nicklass, Ed. Standards Track PAGE 84

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 [AT&T-TR-54016] AT&T Technical Reference, Requirements for Interfacing Digital Terminal Equipment to Services Employing the Extended Superframe Format, Publication 54016, May 1988. [ANSI-T1.403] American National Standard for Telecommunications -- Carrier-to-Customer Installation - DS1 Metallic Interface, T1.403, February 1989. [CCITT-G.703] ITU-T G.703, Physical/Electrical Characteristics of Hierarchical Digital Interfaces, November 2001. [ITU-T-G.704] ITU-T G.704: Synchronous frame structures used at 1544, 6312, 2048, 8488 and 44 736 kbit/s Hierarchical Levels, October 1998. [ANSI-T1.231] American National Standard for Telecommunications -- Digital Hierarchy DS1-- Layer 1 In-Service Digital Transmission Performance Monitoring, T1.231.02, October 2003. [ITU-T-O.162] ITU-T O.162, Equipment To Perform In Service Monitoring On 2048 kbit/s Signals, October 1992. [CCITT-G.821] ITU-T G.821, Error Performance Of An International Digital Connection Forming Part Of An Integrated Services Digital Network, December 2002. [AT&T-TR-62411] AT&T Technical Reference, Technical Reference 62411, ACCUNET T1.5 Service Description And Interface Specification, December 1990. [CCITT-G.706] ITU-T G.706, Frame Alignment and Cyclic Redundancy Check (CRC) Procedures Relating to Basic Frame Structures Defined in Recommendation G.704, April 1991. [CCITT-G.732] ITU-T G.732, Characteristics Of Primary PCM Multiplex Equipment Operating at 2048 kbit/s, November 1988. [ITU-T-G.775] ITU-T G.775: Loss of signal (LOS) and alarm indication signal (AIS) defect detection and clearance criteria, October 1998. [ITU-T-G.826] ITU-T G.826: Error performance parameters and objectives for international, constant bit rate digital paths at or above the primary rate, December 2002. Nicklass, Ed. Standards Track PAGE 85

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 [ANSI-T1.107] American National Standard for Telecommunications -- Digital Hierarchy - Format Specifications, T1.107, January 2002. [RFC 3593] Tesink, K., "Textual Conventions for MIB Modules Using Performance History Based on 15 Minute Intervals", RFC 3593, September 2003. [ITU-T-M.1400] ITU-T M.1400: Designation For Interconnections Among Network Operators, October 2001. [JT-G704] JT-G.704: Synchronous frame structures used at Primary and Secondary Hierarchical Levels, 2002. [JT-G706] JT-G.706: Frame Alignment and Cyclic Redundancy Check (CRC) Procedures. [JT-I431] JT-I.431: ISDN Primary Rate User-Network Interface,Layer 1 Specifications, 2002. 7.2. Informative References [RFC 1213] McCloghrie, K. and M. Rose, "Management Information Base for Network Management of TCP/IP-based internets:MIB-II", STD 17, RFC 1213, March 1991. [RFC 3895] Nicklass, O., "Definitions of Managed Objects for the DS1, E1, DS2, and E2 Interface Types", RFC 3895, September 2004. [RFC 2495] Fowler, D., "Definitions of Managed Objects for the DS1, E1, DS2 and E2 Interface Types", RFC 2495, January 1999. [RFC 1406] Baker, F. and J. Watt, "Definitions of Managed Objects for the DS1 and E1 Interface Types", RFC 1406, January 1993. [AT&T-UM-305] AT&T Information Systems, AT&T ESF DS1 Channel Service Unit User's Manual, 999-100-305, February 1988. [RFC 3896] Nicklass, O., "Definitions of Managed Objects for the DS3/E3 Interface Type", RFC 3896, September 2004. Nicklass, Ed. Standards Track PAGE 86

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 [RFC 3592] Tesink, K., "Definitions of Managed Objects for the Synchronous Optical Network/Synchronous Digital Hierarchy (SONET/SDH) Interface Type", RFC 3592, September 2003. [RFC 2494] Fowler, D., "Definitions of Managed Objects for the DS0 and DS0 Bundle Interface Type", RFC 2494, January 1999. [ANSI-T1.102] American National Standard for Telecommunications -- Digital Hierarchy - Electrical Interfaces, T1.102, December 1993. [RFC 3410] Case, J., Mundy, R., Partain, D., and B. Stewart, "Introduction and Applicability Statements for Internet-Standard Management Framework", RFC 3410, December 2002. Nicklass, Ed. Standards Track PAGE 87

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 Appendix A - Use of dsx1IfIndex and dsx1LineIndex This appendix exists to document the previous use of dsx1IfIndex and dsx1LineIndex and to clarify the relationship of dsx1LineIndex as defined in RFC 1406 with the dsx1LineIndex as defined in this document. The following shows the old and new definitions and the relationship: [New Definition]: "This object should be made equal to ifIndex. The next paragraph describes its previous usage. Making the object equal to ifIndex allows proper use of ifStackTable and ds0/ds0bundle mibs. [Old Definition]: "This object is the identifier of a DS1 Interface on a managed device. If there is an ifEntry that is directly associated with this and only this DS1 interface, it should have the same value as ifIndex. Otherwise, number the dsx1LineIndices with an unique identifier following the rules of choosing a number that is greater than ifNumber and numbering the inside interfaces (e.g., equipment side) with even numbers and outside interfaces (e.g., network side) with odd numbers." When the "Old Definition" was created, it was described this way to allow a manager to treat the value as if it were an ifIndex; i.e., the value would be either: 1) an ifIndex value or 2) a value that was guaranteed to be different from all valid ifIndex values. The new definition is a subset of that definition; i.e., the value is always an ifIndex value. The following is Section 3.1 from RFC 1406: Different physical configurations for the support of SNMP with DS1 equipment exist. To accommodate these scenarios, two different indices for DS1 interfaces are introduced in this MIB. These indices are dsx1IfIndex and dsx1LineIndex. External interface scenario: the SNMP Agent represents all managed DS1 lines as external interfaces (for example, an Agent residing on the device supporting DS1 interfaces directly): For this scenario, all interfaces are assigned an integer value equal to ifIndex, and the following applies: ifIndex=dsx1IfIndex=dsx1LineIndex for all interfaces. Nicklass, Ed. Standards Track PAGE 88

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 The dsx1IfIndex column of the DS1 Configuration table relates each DS1 interface to its corresponding interface (ifIndex) in the Internet-standard MIB (MIB-II STD 17, RFC 1213) [RFC 1213]. External & Internal interface scenario: the SNMP Agents resides on a host external from the device supporting DS1 interfaces (e.g., a router). The Agent represents both the host and the DS1 device. The index dsx1LineIndex is used to not only represent the DS1 interfaces external from the host/DS1-device combination, but also the DS1 interfaces connecting the host and the DS1 device. The index dsx1IfIndex is always equal to ifIndex. Example: A shelf full of CSUs connected to a router. An SNMP Agent residing on the router proxies for itself and the CSU. The router has also an Ethernet interface: +-----+ | | | | | | +---------------------+ |E | | 1.544 MBPS | Line#A | DS1 Link |t | R |---------------+ - - - - - - - - - +------> |h | | | | |e | O | 1.544 MBPS | Line#B | DS1 Link |r | |---------------+ - - - - - - - - - - +------> |n | U | | CSU Shelf | |e | | 1.544 MBPS | Line#C | DS1 Link |t | T |---------------+ - - - -- -- - - - - +------> | | | | | |-----| E | 1.544 MBPS | Line#D | DS1 Link | | |---------------+ - - - - -- - - - - +------> | | R | |_____________________| | | | | +-----+ The assignment of the index values could for example be: ifIndex (= dsx1IfIndex) dsx1LineIndex 1 NA NA (Ethernet) 2 Line#A Router Side 6 2 Line#A Network Side 7 3 Line#B Router Side 8 3 Line#B Network Side 9 4 Line#C Router Side 10 4 Line#C Network Side 11 5 Line#D Router Side 12 5 Line#D Network Side 13 Nicklass, Ed. Standards Track PAGE 89

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 For this example, ifNumber is equal to 5. Note the following description of dsx1LineIndex: the dsx1LineIndex identifies a DS1 Interface on a managed device. If there is an ifEntry that is directly associated with this and only this DS1 interface, it should have the same value as ifIndex. Otherwise, number the dsx1LineIndices with an unique identifier following the rules of choosing a number greater than ifNumber and numbering inside interfaces (e.g., equipment side) with even numbers and outside interfaces (e.g., network side) with odd numbers. If the CSU shelf is managed by itself by a local SNMP Agent, the situation would be: ifIndex (= dsx1IfIndex) dsx1LineIndex 1 Line#A Network Side 1 2 Line#A RouterSide 2 3 Line#B Network Side 3 4 Line#B RouterSide 4 5 Line#C Network Side 5 6 Line#C Router Side 6 7 Line#D Network Side 7 8 Line#D Router Side 8 Appendix B - The Delay Approach to Unavailable Seconds This procedure is illustrated below for a DS1 ESF interface. Similar rules would apply for other DS1, DS2, and E1 interface variants. The procedure guarantees that the statistical counters are correctly updated at all times, although they lag real time by 10 seconds. At the end of each 15-minute interval, the current interval counts are transferred to the most recent interval entry and each interval is shifted up by one position, with the oldest being discarded if necessary in order to make room. The current interval counts then start over from zero. Note, however, that the signal state calculation does not start afresh at each interval boundary; rather, signal state information is retained across interval boundaries. Nicklass, Ed. Standards Track PAGE 90

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 +---------------------------------------------------------------------+ | READ COUNTERS & STATUS INFO FROM HARDWARE | | | | BPV EXZ LOS FE CRC CS AIS SEF OOF LOF RAI G1-G6 SE FE LV SL | +---------------------------------------------------------------------+ | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | V V V V V V V V V V V V V V V V +---------------------------------------------------------------------+ | ACCUM ONE-SEC STATS, CHK ERR THRESHOLDS, & UPDT SIGNAL STATE | | | | |<---------- NEAR END ----------->| |<-------- FAR END ------>| | | | | LCV LES PCV ES CSS BES SES SEFS A/U PCV ES CSS BES SES SEFS A/U | +---------------------------------------------------------------------+ | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | V V V V V V V V | V V V V V V | +------------------------------+ | +----------------------+ | | ONE-SEC DELAY | | | ONE-SEC DELAY | | | (1 OF 10) | | | (1 OF 10) | | +------------------------------+ | +----------------------+ | | | | | | | | | | | | | | | | | / / / / / / / / / / / / / / / / | | | | | | | | | | | | | | | | V V V V V V V V | V V V V V V | +------------------------------+ | +----------------------+ | | ONE-SEC DELAY | | | ONE-SEC DELAY | | | (10 OF 10) | | | (10 OF 10) | | +------------------------------+ | +----------------------+ | | | | | | | | | | | | | | | | | V V V V V V V V V V V V V V V V +---------------------------------------------------------------------+ | UPDATE STATISTICS COUNTERS | | | |<-------------- NEAR END ----------->| |<--------- FAR END --------->| | | |LCV LES PCV ES CSS BES SES SEFS UAS DM PCV ES CSS BES SES SEFS UAS DM| +---------------------------------------------------------------------+ Note that if such a procedure is adopted, there is no current interval data for the first 10 seconds after a system comes up. noSuchInstance must be returned if a management station attempts to access the current interval counters during this time. It is an implementation-specific matter whether an agent assumes that the initial state of the interface is available or unavailable. Nicklass, Ed. Standards Track PAGE 91

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 Appendix C - Changes from Pervious Versions C.1. Changes from RFC 3895 The changes from RFC 3895 [RFC 3895] are the following: (1) Values were added to dsx1LineType to support J1 types. (2) The object dsx1LineImpedance was added. (3) All DM-related objects were deprecated following their removal from ITU performance standards. (4) Relevant text and reference section were updated. (5) Changes in Compliance Statements to include new values. C.2. Changes from RFC 2495 The changes from RFC 2495 [RFC 2495] are the following: (1) The dsx1FracIfIndex SYNTAX matches the description range. (2) A value was added to dsx1TransmitClockSource. (3) Values were added to dsx1LineType. (4) Two objects were added, dsx1LineMode and dsx1LineBuildOut, to better express transceiver mode and LineBuildOut for T1. (5) Reference was added to Circuit Identifier object. (6) Align the DESCRIPTION clauses of few statistic objects with the near-end definition, with the far-end definition, and with [RFC 3593]. (7) Changes in Compliance Statements to include new objects. (8) A typographical error in dsx2E2 was fixed; new name is dsx1E2. C.3. Changes from RFC 1406 The changes from RFC 1406 [RFC 1406] are the following: (1) The Fractional table has been deprecated. (2) This document uses SMIv2. (3) Usage is given for ifTable and ifXTable. (4) Example usage of ifStackTable is included. (5) dsx1IfIndex has been deprecated. (6) Support for DS2 and E2 has been added. (7) Additional lineTypes for DS2, E2, and unframed E1 were added. (8) The definition of valid intervals has been clarified for the case where the agent proxied for other devices. In particular, the treatment of missing intervals has been clarified. (9) An inward loopback has been added. (10) Additional lineStatus bits have been added for Near End in Unavailable Signal State, Carrier Equipment Out of Service, DS2 Payload AIS, and DS2 Performance Threshold. Nicklass, Ed. Standards Track PAGE 92

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 (11) A read-write line Length object has been added. (12) Signal mode of other has been added. (13) Added a lineStatus last change, trap and enabler. (14) The e1(19) ifType has been obsoleted, so this MIB does not list it as a supported ifType. (15) Textual Conventions for statistics objects have been used. (16) A new object, dsx1LoopbackStatus, has been introduced to reflect the loopbacks established on a DS1 interface and the source to the requests. dsx1LoopbackConfig continues to be the desired loopback state while dsx1LoopbackStatus reflects the actual state. (17) A dual loopback has been added to allow the setting of an inward loopback and a line loopback at the same time. (18) An object indicating which channel to use within a parent object (i.e., DS3) has been added. (19) An object has been added to indicate whether or not this DS1/E1 is channelized. (20) Line coding type of B6ZS has been added for DS2. C.4. Companion Documents This document is a companion to the documents that define managed objects for the DS0 [RFC 2494], DS3/E3 [RFC 3896], and Synchronous Optical Network/Synchronous Digital Hierarchy (SONET/SDH) [RFC 3592] Interface Types. Author's Address Orly Nicklass, Editor RAD Data Communications, Ltd. Ziv Tower, 24 Roul Walenberg Tel Aviv, Israel, 69719 Phone: 9723-765-9969 EMail: orly_n@rad.com Nicklass, Ed. Standards Track PAGE 93

RFC 4805 DS1/J1/E1/DS2/E2 MIB March 2007 Full Copyright Statement Copyright © The IETF Trust (2007). This document is subject to the rights, licenses and restrictions contained in BCP 78, and except as set forth therein, the authors retain all their rights. This document and the information contained herein are provided on an "AS IS" basis and THE CONTRIBUTOR, THE ORGANIZATION HE/SHE REPRESENTS OR IS SPONSORED BY (IF ANY), THE INTERNET SOCIETY, THE IETF TRUST AND THE INTERNET ENGINEERING TASK FORCE DISCLAIM ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Intellectual Property The IETF takes no position regarding the validity or scope of any Intellectual Property Rights or other rights that might be claimed to pertain to the implementation or use of the technology described in this document or the extent to which any license under such rights might or might not be available; nor does it represent that it has made any independent effort to identify any such rights. Information on the procedures with respect to rights in RFC documents can be found in BCP 78 and BCP 79. Copies of IPR disclosures made to the IETF Secretariat and any assurances of licenses to be made available, or the result of an attempt made to obtain a general license or permission for the use of such proprietary rights by implementers or users of this specification can be obtained from the IETF on-line IPR repository at http://www.ietf.org/ipr. The IETF invites any interested party to bring to its attention any copyrights, patents or patent applications, or other proprietary rights that may cover technology that may be required to implement this standard. Please address the information to the IETF at ietf-ipr@ietf.org. Acknowledgement Funding for the RFC Editor function is currently provided by the Internet Society. Nicklass, Ed. Standards Track PAGE 94