|
|
|
|
|
IETF RFC 1659
Definitions of Managed Objects for RS-232-like Hardware Devices using SMIv2
Last modified on Tuesday, July 19th, 1994
Permanent link to RFC 1659
Search GitHub Wiki for RFC 1659
Show other RFCs mentioning RFC 1659
Network Working Group B. Stewart
Request for Comments: 1659 Xyplex, Inc.
Obsoletes: 1317 July 1994
Category: Standards Track
Definitions of Managed Objects for RS-232-like Hardware Devices
using SMIv2
Status of this Memo
This document specifies an Internet standards track protocol for the
Internet community, and requests discussion and suggestions for
improvements. Please refer to the current edition of the "Internet
Official Protocol Standards" (STD 1) for the standardization state
and status of this protocol. Distribution of this memo is unlimited.
Table of Contents
1. Introduction ................................................ 1
2. The SNMPv2 Network Management Framework ..................... 1
2.1 Object Definitions ......................................... 2
3. Overview .................................................... 2
3.1 Relationship to Interface MIB .............................. 3
4. Definitions ................................................. 3
5. Acknowledgements ............................................ 20
6. References .................................................. 20
7. Security Considerations ..................................... 21
8. Author's Address ............................................ 21
1. Introduction
This memo defines an extension to the Management Information Base
(MIB) for use with network management protocols in the Internet
community. In particular, it defines objects for the management of
RS-232-like devices.
2. The SNMPv2 Network Management Framework
The SNMPv2 Network Management Framework consists of four major
components. They are:
o RFC 1442 [1] which defines the SMI, the mechanisms used for
describing and naming objects for the purpose of management.
o STD 17, RFC 1213 [2] defines MIB-II, the core set of managed
objects for the Internet suite of protocols.
Stewart PAGE 1
RFC 1659 RS-232-like MIB July 1994
o RFC 1445 [3] which defines the administrative and other
architectural aspects of the framework.
o RFC 1448 [4] which defines the protocol used for network
access to managed objects.
The Framework permits new objects to be defined for the purpose of
experimentation and evaluation.
2.1. Object Definitions
Managed objects are accessed via a virtual information store, termed
the Management Information Base or MIB. Objects in the MIB are
defined using the subset of Abstract Syntax Notation One (ASN.1)
defined in the SMI. In particular, each object object type is named
by an OBJECT IDENTIFIER, an administratively assigned name. The
object type together with an object instance serves to uniquely
identify a specific instantiation of the object. For human
convenience, we often use a textual string, termed the descriptor, to
refer to the object type.
3. Overview
The RS-232-like Hardware Device MIB applies to interface ports that
might logically support the Interface MIB, a Transmission MIB, or the
Character MIB. The most common example is an RS-232 port with modem
signals.
The RS-232-like Hardware Device MIB is mandatory for all systems that
have such a hardware port supporting services managed through some
other MIB.
The MIB includes multiple similar types of hardware, and as a result
contains objects not applicable to all of those types. The
compliance definitions herein thus have a general group for all
implementations, and separate groups for the different types of
ports, such as asynchronous and synchronous.
The RS-232-like Hardware Port MIB includes RS-232, RS-422, RS-423,
V.35, and other asynchronous or synchronous, serial physical links
with a similar set of control signals.
The MIB contains objects that relate to physical layer connections.
Such connections may provide interesting hardware signals (other than
for basic data transfer), such as RNG and DCD. Hardware ports also
have such attributes as speed and bits per character.
Stewart PAGE 2
RFC 1659 RS-232-like MIB July 1994
The MIB comprises one base object and four tables, detailed in the
following sections. The tables contain objects for all ports,
asynchronous ports, and input and output control signals.
3.1. Relationship to Interface MIB
The RS-232-like MIB is one of many MIBs designed for layered use as
described in the Interface MIB [5]. In most implementations where it
is present, it will be in the lowest interface sublayer, that is, the
RS-232-like MIB represents the physical layer, providing service to
higher layers such as the Character MIB [6] or PPP MIB [7].
The Interface MIB's ifTestTable and ifRcvAddressTable are not
relevant to the RS-232-like MIB.
The RS-232-like MIB is relevant for ifType values rs232(33), v35(45),
and perhaps others.
The RS-232-like MIB requires the conformance groups ifGeneralGroup,
and ifFixedLengthGroup.
The value of ifSpeed is the same as rs232PortOutSpeed.
Usefulness of error counters in this MIB depends on the octet
counters in ifFixedLengthGroup.
4. Definitions
RS-232-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
Counter32, Integer32
FROM SNMPv2-SMI
InterfaceIndex
FROM IF-MIB
transmission
FROM RFC 1213-MIB
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF;
rs232 MODULE-IDENTITY
LAST-UPDATED "9405261700Z"
ORGANIZATION "IETF Character MIB Working Group"
CONTACT-INFO
" Bob Stewart
Postal: Xyplex, Inc.
Stewart PAGE 3
RFC 1659 RS-232-like MIB July 1994
295 Foster Street
Littleton, MA 01460
Tel: 508-952-4816
Fax: 508-952-4887
E-mail: rlstewart@eng.xyplex.com"
DESCRIPTION
"The MIB module for RS-232-like hardware devices."
::= { transmission 33 }
-- Generic RS-232-like information
rs232Number OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ports (regardless of their current
state) in the RS-232-like general port table."
::= { rs232 1 }
-- RS-232-like General Port Table
rs232PortTable OBJECT-TYPE
SYNTAX SEQUENCE OF Rs232PortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of port entries. The number of entries is
given by the value of rs232Number."
::= { rs232 2 }
rs232PortEntry OBJECT-TYPE
SYNTAX Rs232PortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Status and parameter values for a port."
INDEX { rs232PortIndex }
::= { rs232PortTable 1 }
Rs232PortEntry ::=
SEQUENCE {
rs232PortIndex
InterfaceIndex,
rs232PortType
Stewart PAGE 4
RFC 1659 RS-232-like MIB July 1994
INTEGER,
rs232PortInSigNumber
Integer32,
rs232PortOutSigNumber
Integer32,
rs232PortInSpeed
Integer32,
rs232PortOutSpeed
Integer32,
rs232PortInFlowType
INTEGER,
rs232PortOutFlowType
INTEGER
}
rs232PortIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of ifIndex for the port. By convention
and if possible, hardware port numbers map directly
to external connectors. The value for each port must
remain constant at least from one re-initialization
of the network management agent to the next."
::= { rs232PortEntry 1 }
rs232PortType OBJECT-TYPE
SYNTAX INTEGER { other(1), rs232(2), rs422(3),
rs423(4), v35(5), x21(6) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port's hardware type."
::= { rs232PortEntry 2 }
rs232PortInSigNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of input signals for the port in the
input signal table (rs232PortInSigTable). The table
contains entries only for those signals the software
can detect and that are useful to observe."
::= { rs232PortEntry 3 }
Stewart PAGE 5
RFC 1659 RS-232-like MIB July 1994
rs232PortOutSigNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of output signals for the port in the
output signal table (rs232PortOutSigTable). The
table contains entries only for those signals the
software can assert and that are useful to observe."
::= { rs232PortEntry 4 }
rs232PortInSpeed OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port's input speed in bits per second. Note that
non-standard values, such as 9612, are probably not allowed
on most implementations."
::= { rs232PortEntry 5 }
rs232PortOutSpeed OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port's output speed in bits per second. Note that
non-standard values, such as 9612, are probably not allowed
on most implementations."
::= { rs232PortEntry 6 }
rs232PortInFlowType OBJECT-TYPE
SYNTAX INTEGER { none(1), ctsRts(2), dsrDtr(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port's type of input flow control. 'none'
indicates no flow control at this level.
'ctsRts' and 'dsrDtr' indicate use of the indicated
hardware signals."
::= { rs232PortEntry 7 }
rs232PortOutFlowType OBJECT-TYPE
SYNTAX INTEGER { none(1), ctsRts(2), dsrDtr(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port's type of output flow control. 'none'
Stewart PAGE 6
RFC 1659 RS-232-like MIB July 1994
indicates no flow control at this level.
'ctsRts' and 'dsrDtr' indicate use of the indicated
hardware signals."
::= { rs232PortEntry 8 }
-- RS-232-like Asynchronous Port Table
rs232AsyncPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF Rs232AsyncPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of asynchronous port entries. Entries need
not exist for synchronous ports."
::= { rs232 3 }
rs232AsyncPortEntry OBJECT-TYPE
SYNTAX Rs232AsyncPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Status and parameter values for an asynchronous
port."
INDEX { rs232AsyncPortIndex }
::= { rs232AsyncPortTable 1 }
Rs232AsyncPortEntry ::=
SEQUENCE {
rs232AsyncPortIndex
InterfaceIndex,
rs232AsyncPortBits
INTEGER,
rs232AsyncPortStopBits
INTEGER,
rs232AsyncPortParity
INTEGER,
rs232AsyncPortAutobaud
INTEGER,
rs232AsyncPortParityErrs
Counter32,
rs232AsyncPortFramingErrs
Counter32,
rs232AsyncPortOverrunErrs
Counter32
}
Stewart PAGE 7
RFC 1659 RS-232-like MIB July 1994
rs232AsyncPortIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value for each port. Its value is the
same as rs232PortIndex for the port."
::= { rs232AsyncPortEntry 1 }
rs232AsyncPortBits OBJECT-TYPE
SYNTAX INTEGER (5..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port's number of bits in a character."
::= { rs232AsyncPortEntry 2 }
rs232AsyncPortStopBits OBJECT-TYPE
SYNTAX INTEGER { one(1), two(2),
oneAndHalf(3), dynamic(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port's number of stop bits."
::= { rs232AsyncPortEntry 3 }
rs232AsyncPortParity OBJECT-TYPE
SYNTAX INTEGER { none(1), odd(2), even(3),
mark(4), space(5) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port's sense of a character parity bit."
::= { rs232AsyncPortEntry 4 }
rs232AsyncPortAutobaud OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A control for the port's ability to automatically
sense input speed.
When rs232PortAutoBaud is 'enabled', a port may
autobaud to values different from the set values for
speed, parity, and character size. As a result a
network management system may temporarily observe
values different from what was previously set."
Stewart PAGE 8
RFC 1659 RS-232-like MIB July 1994
::= { rs232AsyncPortEntry 5 }
rs232AsyncPortParityErrs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of characters with a parity error,
input from the port since system re-initialization
and while the port state was 'up' or 'test'."
::= { rs232AsyncPortEntry 6 }
rs232AsyncPortFramingErrs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of characters with a framing error,
input from the port since system re-initialization
and while the port state was 'up' or 'test'."
::= { rs232AsyncPortEntry 7 }
rs232AsyncPortOverrunErrs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of characters with an overrun error,
input from the port since system re-initialization
and while the port state was 'up' or 'test'."
::= { rs232AsyncPortEntry 8 }
-- RS-232-like Synchronous Port Table
rs232SyncPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF Rs232SyncPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of asynchronous port entries. Entries need
not exist for synchronous ports."
::= { rs232 4 }
rs232SyncPortEntry OBJECT-TYPE
SYNTAX Rs232SyncPortEntry
MAX-ACCESS not-accessible
STATUS current
Stewart PAGE 9
RFC 1659 RS-232-like MIB July 1994
DESCRIPTION
"Status and parameter values for a synchronous
port."
INDEX { rs232SyncPortIndex }
::= { rs232SyncPortTable 1 }
Rs232SyncPortEntry ::=
SEQUENCE {
rs232SyncPortIndex
InterfaceIndex,
rs232SyncPortClockSource
INTEGER,
rs232SyncPortFrameCheckErrs
Counter32,
rs232SyncPortTransmitUnderrunErrs
Counter32,
rs232SyncPortReceiveOverrunErrs
Counter32,
rs232SyncPortInterruptedFrames
Counter32,
rs232SyncPortAbortedFrames
Counter32,
rs232SyncPortRole
INTEGER,
rs232SyncPortEncoding
INTEGER,
rs232SyncPortRTSControl
INTEGER,
rs232SyncPortRTSCTSDelay
Integer32,
rs232SyncPortMode
INTEGER,
rs232SyncPortIdlePattern
INTEGER,
rs232SyncPortMinFlags
Integer32
}
rs232SyncPortIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value for each port. Its value is the
same as rs232PortIndex for the port."
::= { rs232SyncPortEntry 1 }
Stewart PAGE 10
RFC 1659 RS-232-like MIB July 1994
rs232SyncPortClockSource OBJECT-TYPE
SYNTAX INTEGER { internal(1), external(2), split(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Source of the port's bit rate clock. 'split' means
the tranmit clock is internal and the receive clock
is external."
::= { rs232SyncPortEntry 2 }
rs232SyncPortFrameCheckErrs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of frames with an invalid frame check
sequence, input from the port since system
re-initialization and while the port state was 'up'
or 'test'."
::= { rs232SyncPortEntry 3 }
rs232SyncPortTransmitUnderrunErrs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of frames that failed to be
transmitted on the port since system
re-initialization and while the port state was 'up'
or 'test' because data was not available to the
transmitter in time."
::= { rs232SyncPortEntry 4 }
rs232SyncPortReceiveOverrunErrs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of frames that failed to be received
on the port since system re-initialization and while
the port state was 'up' or 'test' because the
receiver did not accept the data in time."
::= { rs232SyncPortEntry 5 }
rs232SyncPortInterruptedFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
Stewart PAGE 11
RFC 1659 RS-232-like MIB July 1994
DESCRIPTION
"Total number of frames that failed to be received
or transmitted on the port due to loss of modem
signals since system re-initialization and while the
port state was 'up' or 'test'."
::= { rs232SyncPortEntry 6 }
rs232SyncPortAbortedFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames aborted on the port due to
receiving an abort sequence since system
re-initialization and while the port state was 'up'
or 'test'."
::= { rs232SyncPortEntry 7 }
rs232SyncPortRole OBJECT-TYPE
SYNTAX INTEGER { dte(1), dce(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The role the device is playing that is using this port.
dte means the device is performing the role of
data terminal equipment
dce means the device is performing the role of
data circuit-terminating equipment."
DEFVAL { dce }
::= { rs232SyncPortEntry 8 }
rs232SyncPortEncoding OBJECT-TYPE
SYNTAX INTEGER { nrz(1), nrzi(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The bit stream encoding technique that is in effect
for this port.
nrz for Non-Return to Zero encoding
nrzi for Non-Return to Zero Inverted encoding."
DEFVAL { nrz }
::= { rs232SyncPortEntry 9 }
rs232SyncPortRTSControl OBJECT-TYPE
SYNTAX INTEGER { controlled(1), constant(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
Stewart PAGE 12
RFC 1659 RS-232-like MIB July 1994
"The method used to control the Request To Send (RTS)
signal.
controlled when the DTE is asserts RTS each time
data needs to be transmitted and drops
RTS at some point after data
transmission begins.
If rs232SyncPortRole is 'dte', the
RTS is an output signal. The device
will issue a RTS and wait for a CTS
from the DCE before starting to
transmit.
If rs232SyncPortRole is 'dce', the
RTS is an input signal. The device
will issue a CTS only after having
received RTS and waiting the
rs232SyncPortRTSCTSDelay interval.
constant when the DTE constantly asserts RTS."
DEFVAL { constant }
::= { rs232SyncPortEntry 10 }
rs232SyncPortRTSCTSDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The interval (in milliseconds) that the DCE must wait
after it sees RTS asserted before asserting CTS. This
object exists in support of older synchronous devices
that cannot recognize CTS within a certain interval
after it asserts RTS."
DEFVAL { 0 }
::= { rs232SyncPortEntry 11 }
rs232SyncPortMode OBJECT-TYPE
SYNTAX INTEGER { fdx(1), hdx(2), simplex-receive(3),
simplex-send(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The mode of operation of the port with respect to the
direction and simultaneity of data transfer.
Stewart PAGE 13
RFC 1659 RS-232-like MIB July 1994
fdx when frames on the data link can be
transmitted and received at the same
time
hdx when frames can either be received
from the data link or transmitted
onto the data link but not at the
same time.
simplex-receive when frames can only be received on
this data link.
simplex-send when frames can only be sent on this
data link."
DEFVAL { fdx }
::= { rs232SyncPortEntry 12 }
rs232SyncPortIdlePattern OBJECT-TYPE
SYNTAX INTEGER { mark(1), space(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The bit pattern used to indicate an idle line."
DEFVAL { space }
::= { rs232SyncPortEntry 13 }
rs232SyncPortMinFlags OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The minimum number of flag patterns this port needs in
order to recognize the end of one frame and the start
of the next. Plausible values are 1 and 2."
DEFVAL { 2 }
::= { rs232SyncPortEntry 14 }
-- Input Signal Table
rs232InSigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Rs232InSigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of port input control signal entries
implemented and visible to the software on the port,
and useful to monitor."
Stewart PAGE 14
RFC 1659 RS-232-like MIB July 1994
::= { rs232 5 }
rs232InSigEntry OBJECT-TYPE
SYNTAX Rs232InSigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Input control signal status for a hardware port."
INDEX { rs232InSigPortIndex, rs232InSigName }
::= { rs232InSigTable 1 }
Rs232InSigEntry ::=
SEQUENCE {
rs232InSigPortIndex
InterfaceIndex,
rs232InSigName
INTEGER,
rs232InSigState
INTEGER,
rs232InSigChanges
Counter32
}
rs232InSigPortIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of rs232PortIndex for the port to which
this entry belongs."
::= { rs232InSigEntry 1 }
rs232InSigName OBJECT-TYPE
SYNTAX INTEGER { rts(1), cts(2), dsr(3), dtr(4), ri(5),
dcd(6), sq(7), srs(8), srts(9),
scts(10), sdcd(11) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identification of a hardware signal, as follows:
rts Request to Send
cts Clear to Send
dsr Data Set Ready
dtr Data Terminal Ready
ri Ring Indicator
dcd Received Line Signal Detector
sq Signal Quality Detector
Stewart PAGE 15
RFC 1659 RS-232-like MIB July 1994
srs Data Signaling Rate Selector
srts Secondary Request to Send
scts Secondary Clear to Send
sdcd Secondary Received Line Signal Detector
"
REFERENCE
"EIA Standard RS-232-C, August 1969."
::= { rs232InSigEntry 2 }
rs232InSigState OBJECT-TYPE
SYNTAX INTEGER { none(1), on(2), off(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current signal state."
::= { rs232InSigEntry 3 }
rs232InSigChanges OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the signal has changed from
'on' to 'off' or from 'off' to 'on'."
::= { rs232InSigEntry 4 }
-- Output Signal Table
rs232OutSigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Rs232OutSigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of port output control signal entries
implemented and visible to the software on the port,
and useful to monitor."
::= { rs232 6 }
rs232OutSigEntry OBJECT-TYPE
SYNTAX Rs232OutSigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Output control signal status for a hardware port."
INDEX { rs232OutSigPortIndex, rs232OutSigName }
::= { rs232OutSigTable 1 }
Stewart PAGE 16
RFC 1659 RS-232-like MIB July 1994
Rs232OutSigEntry ::=
SEQUENCE {
rs232OutSigPortIndex
InterfaceIndex,
rs232OutSigName
INTEGER,
rs232OutSigState
INTEGER,
rs232OutSigChanges
Counter32
}
rs232OutSigPortIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of rs232PortIndex for the port to which
this entry belongs."
::= { rs232OutSigEntry 1 }
rs232OutSigName OBJECT-TYPE
SYNTAX INTEGER { rts(1), cts(2), dsr(3), dtr(4), ri(5),
dcd(6), sq(7), srs(8), srts(9),
scts(10), sdcd(11) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identification of a hardware signal, as follows:
rts Request to Send
cts Clear to Send
dsr Data Set Ready
dtr Data Terminal Ready
ri Ring Indicator
dcd Received Line Signal Detector
sq Signal Quality Detector
srs Data Signaling Rate Selector
srts Secondary Request to Send
scts Secondary Clear to Send
sdcd Secondary Received Line Signal Detector
"
REFERENCE
"EIA Standard RS-232-C, August 1969."
::= { rs232OutSigEntry 2 }
rs232OutSigState OBJECT-TYPE
SYNTAX INTEGER { none(1), on(2), off(3) }
Stewart PAGE 17
RFC 1659 RS-232-like MIB July 1994
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current signal state."
::= { rs232OutSigEntry 3 }
rs232OutSigChanges OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the signal has changed from
'on' to 'off' or from 'off' to 'on'."
::= { rs232OutSigEntry 4 }
-- conformance information
rs232Conformance OBJECT IDENTIFIER ::= { rs232 7 }
rs232Groups OBJECT IDENTIFIER ::= { rs232Conformance 1 }
rs232Compliances OBJECT IDENTIFIER ::= { rs232Conformance 2 }
-- compliance statements
rs232Compliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for SNMPv2 entities
which have RS-232-like hardware interfaces."
MODULE -- this module
MANDATORY-GROUPS { rs232Group }
GROUP rs232AsyncGroup
DESCRIPTION
"The Asynch group is mandatory only for those
SNMPv2 entities which have asynchronous
interfaces Rs-232-like."
GROUP rs232SyncGroup
DESCRIPTION
"The Synch group is mandatory only for those
SNMPv2 entities which have synchronous
interfaces Rs-232-like."
::= { rs232Compliances 1 }
Stewart PAGE 18
RFC 1659 RS-232-like MIB July 1994
-- units of conformance
rs232Group OBJECT-GROUP
OBJECTS { rs232Number, rs232PortIndex, rs232PortType,
rs232PortInSigNumber, rs232PortOutSigNumber,
rs232PortInSpeed, rs232PortOutSpeed,
rs232PortInFlowType, rs232PortOutFlowType,
rs232InSigPortIndex, rs232InSigName,
rs232InSigState, rs232InSigChanges,
rs232OutSigPortIndex, rs232OutSigName,
rs232OutSigState, rs232OutSigChanges }
STATUS current
DESCRIPTION
"A collection of objects providing information
applicable to all RS-232-like interfaces."
::= { rs232Groups 1 }
rs232AsyncGroup OBJECT-GROUP
OBJECTS { rs232AsyncPortIndex, rs232AsyncPortBits,
rs232AsyncPortStopBits, rs232AsyncPortParity,
rs232AsyncPortAutobaud, rs232AsyncPortParityErrs,
rs232AsyncPortFramingErrs, rs232AsyncPortOverrunErrs }
STATUS current
DESCRIPTION
"A collection of objects providing information
applicable to asynchronous RS-232-like interfaces."
::= { rs232Groups 2 }
rs232SyncGroup OBJECT-GROUP
OBJECTS { rs232SyncPortIndex, rs232SyncPortClockSource,
rs232SyncPortFrameCheckErrs,
rs232SyncPortTransmitUnderrunErrs,
rs232SyncPortReceiveOverrunErrs,
rs232SyncPortInterruptedFrames,
rs232SyncPortAbortedFrames }
STATUS current
DESCRIPTION
"A collection of objects providing information
applicable to synchronous RS-232-like interfaces."
::= { rs232Groups 3 }
rs232SyncSDLCGroup OBJECT-GROUP
OBJECTS { rs232SyncPortRole,
rs232SyncPortEncoding,
rs232SyncPortRTSControl,
rs232SyncPortRTSCTSDelay,
rs232SyncPortMode,
rs232SyncPortIdlePattern,
Stewart PAGE 19
RFC 1659 RS-232-like MIB July 1994
rs232SyncPortMinFlags }
STATUS current
DESCRIPTION
"A collection of objects providing information
applicable to synchronous RS-232-like interfaces
running SDLC."
::= { rs232Groups 4 }
END
5. Acknowledgements
This memo was produced by the IETF Character MIB Working Group.
6. References
[1] Case, J., McCloghrie, K., Rose, M., and S. Waldbusser, "Structure
of Management Information for version 2 of the Simple Network
Management Protocol (SNMPv2)", RFC 1442, SNMP Research,Inc.,
Hughes LAN Systems, Dover Beach Consulting, Inc., Carnegie Mellon
University, April 1993.
[2] McCloghrie, K., and M. Rose, Editors, "Management Information
Base for Network Management of TCP/IP-based internets: MIB-II",
STD 17, RFC 1213, Hughes LAN Systems, Performance Systems
International, March 1991.
[3] Galvin, J., and K. McCloghrie, "Administrative Model for version
2 of the Simple Network Management Protocol (SNMPv2)", RFC 1445,
Trusted Information Systems, Hughes LAN Systems, April 1993.
[4] Case, J., McCloghrie, K., Rose, M., and S. Waldbusser, "Protocol
Operations for version 2 of the Simple Network Management
Protocol (SNMPv2)", RFC 1448, SNMP Research,Inc., Hughes LAN
Systems, Dover Beach Consulting, Inc., Carnegie Mellon
University, April 1993.
[5] McCloghrie, K., and F. Kastenholz, "Evolution of the Interfaces
Group of MIB-II", RFC 1573, Hughes LAN Systems, FTP Software,
January 1994.
[6] Stewart, B., "Definitions of Managed Objects for Character Stream
Devices using SMIv2", RFC 1658, Xyplex, Inc., July 1994.
[7] Kastenholz, F., "The Definitions of Managed Objects for the Link
Control Protocol of the Point-to-Point Protocol", RFC 1471, FTP
Software, Inc., June 1993.
Stewart PAGE 20
RFC 1659 RS-232-like MIB July 1994
7. Security Considerations
Security issues are not discussed in this memo.
8. Author's Address
Bob Stewart
Xyplex, Inc.
295 Foster Street
Littleton, MA 01460
Phone: 508-952-4816
Fax: 508-952-4887
EMail: rlstewart@eng.xyplex.com
Stewart PAGE 21
Definitions of Managed Objects for RS-232-like Hardware Devices using SMIv2
RFC TOTAL SIZE: 36479 bytes
PUBLICATION DATE: Tuesday, July 19th, 1994
LEGAL RIGHTS: The IETF Trust (see BCP 78)
|