Network Working Group                                         C. Hedrick
Request for Comments: 1079                            Rutgers University
                                                           December 1988


                      Telnet Terminal Speed Option

 Status of This Memo

   This RFC specifies a standard for the Internet community.  Hosts on
   the Internet that exchange terminal speed information within the
   Telnet protocol are expected to adopt and implement this standard.
   Distribution of this memo is unlimited.

   This standard is modelled on RFC 930 [1], the telnet terminal type
   option.  Much of the text of this document is copied from that RFC.

Motivation

   Most operating systems have provisions to keep track of the speed
   (bit rate) of directly attached terminals and modems.  This
   information is used to control various timing-dependent display
   processes, e.g., the number of padding characters used for delay.
   Some software also has user interfaces that are tuned differently for
   fast and slow terminals.  The purpose of this option is to provide
   similar information for telnet connections.

1. Command Name and Code

      TERMINAL-SPEED

      Code = 32

2. Command Meanings

      IAC WILL TERMINAL-SPEED

         Sender is willing to send terminal speed information in a
         subsequent sub-negotiation.

      IAC WON'T TERMINAL-SPEED

         Sender refuses to send terminal speed information.






Hedrick                                                      PAGE 1 top


RFC 1079 Telnet Terminal Speed Option December 1988 IAC DO TERMINAL-SPEED Sender is willing to receive terminal speed information in a subsequent sub-negotiation. IAC DON'T TERMINAL-SPEED Sender refuses to accept terminal speed information. IAC SB TERMINAL-SPEED SEND IAC SE Sender requests receiver to transmit his (the receiver's) terminal speed. The code for SEND is 1. (See below.) IAC SB TERMINAL-SPEED IS ... IAC SE Sender is stating his terminal speed. The code for IS is 0. (See below.) 3. Default WON'T TERMINAL-SPEED Terminal speed information will not be exchanged. DON'T TERMINAL-SPEED Terminal speed information will not be exchanged. 4. Description of the Option WILL and DO are used only to obtain and grant permission for future discussion. The actual exchange of status information occurs within option subcommands (IAC SB TERMINAL-SPEED...). Once the two hosts have exchanged a WILL and a DO, the sender of the DO TERMINAL-SPEED is free to request speed information. Only the sender of the DO may send requests (IAC SB TERMINAL-SPEED SEND IAC SE) and only the sender of the WILL may transmit actual speed information (within an IAC SB TERMINAL-SPEED IS ... IAC SE command). Terminal speed information may not be sent spontaneously, but only in response to a request. The terminal speed information is an NVT ASCII string. This string contains the decimal representation of the transmit and receive speeds of the terminal, separated by a comma, e.g., 9600,100 Hedrick PAGE 2 top

RFC 1079 Telnet Terminal Speed Option December 1988 No leading zeros may be included. No extraneous characters such as spaces may be included. The following is an example of use of the option: Host1: IAC DO TERMINAL-SPEED Host2: IAC WILL TERMINAL-SPEED (Host1 is now free to request status information at any time.) Host1: IAC SB TERMINAL-SPEED SEND IAC SE Host2: IAC SB TERMINAL-SPEED IS "1200,1200" IAC SE (This command is 15 octets.) 5. Implementation Suggestions Many systems allow only certain discrete terminal speeds. In such cases it is possible that a speed may be received that does not match one of the allowed values. We suggest that you pick the nearest speed that is allowed, rounding in a "safe" direction. Safety will depend upon the use of the speed information. If it is being used for padding, it is best to round up, since too much padding is better than too little. Reference [1] Solomon, M., and Wimmers, E., "Telnet Terminal Type Option", RFC 930, January, 1985 [AAuthor's Address: Charles Hedrick Rutgers University Center for Computer and Information Services Hill Center, Busch Campus P.O. Box 879 Piscataway, NJ 08855-0879 Phone: (201) 932-3088 Email: HEDRICK@ARAMIS.RUTGERS.EDU Hedrick PAGE 3 top